Calibration techniques and datatype extraction for time-resolved optical tomography

被引:68
作者
Hillman, EMC
Hebden, JC
Schmidt, FEW
Arridge, SR
Schweiger, M
Dehghani, H
Delpy, DT
机构
[1] UCL, Dept Med Phys, London WC1E 6JA, England
[2] UCL, Dept Comp Sci, London WC1E 6JA, England
关键词
D O I
10.1063/1.1287748
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article describes the preprocessing and calibration methods currently applied to data acquired with the University College London multichannel time-resolved optical tomography system. We briefly outline the imaging system and describe the features of our experimentally collected data, sources of stochastic noise, and systematic errors. We examine two methods of calibrating data: "difference imaging" using two image data sets with and without the features of interest to produce an image, and "absolute imaging" using an independent calibration measurement. We describe the methods developed to apply each calibration to raw data. Although the difference imaging performed is found to produce images with fewer artifacts, analysis indicates that it will not be directly applicable for clinical applications. Also examined are the effects of using a two dimensional (2D) reconstruction scheme to produce images from measured data. For absolute imaging, artifacts are shown to dominate such images even in the case of a homogeneous third dimension. The feasibility of deriving an ad-hoc correction factor to allow the use of a 2D reconstruction for measured data is examined, and is shown to reduce artifact. Difference imaging is demonstrated to be more robust to such effects. (C) 2000 American Institute of Physics. [S0034-6748(00)03609-1].
引用
收藏
页码:3415 / 3427
页数:13
相关论文
共 26 条
[1]  
Arridge SR, 2000, INT J IMAG SYST TECH, V11, P2, DOI 10.1002/(SICI)1098-1098(2000)11:1<2::AID-IMA2>3.0.CO
[2]  
2-J
[3]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[4]   THE THEORETICAL BASIS FOR THE DETERMINATION OF OPTICAL PATHLENGTHS IN TISSUE - TEMPORAL AND FREQUENCY-ANALYSIS [J].
ARRIDGE, SR ;
COPE, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (07) :1531-1560
[5]   Nonuniqueness in diffusion-based optical tomography [J].
Arridge, SR ;
Lionheart, WRB .
OPTICS LETTERS, 1998, 23 (11) :882-884
[6]  
ARRIDGE SR, 1995, P SOC PHOTO-OPT INS, V2389, P378
[7]   In vivo local determination of tissue optical properties:: applications to human brain [J].
Bevilacqua, F ;
Piguet, D ;
Marquet, P ;
Gross, JD ;
Tromberg, BJ ;
Depeursinge, C .
APPLIED OPTICS, 1999, 38 (22) :4939-4950
[8]   Systematic diffuse optical image errors resulting from uncertainty in the background optical properties [J].
Cheng, XF ;
Boas, DA .
OPTICS EXPRESS, 1999, 4 (08) :299-307
[9]   Quantification in tissue near-infrared spectroscopy [J].
Delpy, DT ;
Cope, M .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1997, 352 (1354) :649-659
[10]   Multichannel time-resolved optical tomographic imaging system [J].
Eda, H ;
Oda, I ;
Ito, Y ;
Wada, Y ;
Oikawa, Y ;
Tsunazawa, Y ;
Takada, M ;
Tsuchiya, Y ;
Yamashita, Y ;
Oda, M ;
Sassaroli, A ;
Yamada, Y ;
Tamura, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (09) :3595-3602