The role of tear physiology in ocular surface temperature

被引:147
作者
Craig, JP
Singh, I
Tomlinson, A
Morgan, PB
Efron, N
机构
[1] Univ Auckland, Discipline Ophthalmol, Auckland 1001, New Zealand
[2] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 0BA, Lanark, Scotland
[3] Univ Manchester, Dept Optometry & Vis Sci, Manchester M60 1QD, Lancs, England
关键词
dry eye; evaporation; physiology; tear film; temperature; thermography;
D O I
10.1038/eye.2000.156
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To determine whether the more rapid cooling of the tear film in dry eyes is related to other tear film parameters, a battery of tear physiology tests was performed on dry eye patients and control subjects. Methods Tear evaporation rate was measured with a modified Servomed (vapour pressure) evaporimeter and ocular temperature with an NEC San-ei 6T62 Thermo Tracer in 9 patients diagnosed as having dry eye and in 13 healthy control subjects. Variability in temperature across the ocular surface was described by the temperature variation factor (TVF). Lipid layer structure and tear film stability were assessed with the Keeler Tearscope and tear osmolality was measured by freezing point depression nanolitre osmometry. Results The data were explored by principal component analysis. The subjects with and without dry eye could be separated into two distinct groups entirely on the basis of their tear physiology. Dry eye patients exhibited higher tear evaporation rates, osmolalities and TVF, lower tear film stabilities and poorer-quality lipid layers than the control subjects. A significant linear relationship was found to exist between tear evaporation rate and TVF for all subjects (R-2 = 0.242, p = 0.024). Conclusions Rapid cooling of the tear film in dry eyes appears to be related to the reduced stability of the tears and the increased rate of evaporation. The higher latent heat of vaporisation, associated with the increased evaporation in dry eyes, may account for the increased rate of cooling of the tear film in this condition.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 44 条
[1]   INFLUENCE OF AGE ON THE TEMPERATURE OF THE ANTERIOR SEGMENT OF THE EYE - MEASUREMENTS BY INFRARED THERMOMETRY [J].
ALIO, J ;
PADRON, M .
OPHTHALMIC RESEARCH, 1982, 14 (03) :153-159
[2]  
BENJAMIN WJ, 1983, INVEST OPHTH VIS SCI, V24, P1624
[3]   AGE, GENDER, AND TEAR BREAK-UP TIME [J].
CHO, P ;
YAP, M .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (10) :828-831
[4]   Importance of the lipid layer in human tear film stability and evaporation [J].
Craig, JP ;
Tomlinson, A .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (01) :8-13
[5]   EFFECT OF AGE ON TEAR OSMOLALITY [J].
CRAIG, JP ;
TOMLINSON, A .
OPTOMETRY AND VISION SCIENCE, 1995, 72 (10) :713-717
[6]  
CRAIG JP, 1995, THESIS GLASGOW CALED, P182
[7]  
CRAIG JP, 1988, ADV EXP MED BIOL, V438, P411
[8]  
Doane M G, 1994, Adv Exp Med Biol, V350, P489
[9]  
EFRON N, 1989, CURR EYE RES, V8, P901
[10]   Corneal temperature in patients with dry eye evaluated by infrared radiation thermometry [J].
Fujishima, H ;
Toda, I ;
Yamada, M ;
Sato, N ;
Tsubota, K .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (01) :29-32