Initial human experience with the Amplatzer perimembranous ventricular septal occluder device

被引:118
作者
Bass, JL
Kalra, GS
Arora, R
Masura, J
Gavora, P
Thanopoulos, BD
Torres, W
Sievert, H
Carminati, M
Fischer, G
Ewert, P
机构
[1] Univ Minnesota, Dept Pediat Cardiol, Minneapolis, MN 55455 USA
[2] GB Pant Hosp, Dept Cardiol, New Delhi 110002, India
[3] Childrens Univ Hosp, Dept Intervent Cardiol, Bratislava, Slovakia
[4] Aghia Sophia Childrens Hosp, Dept Cardiol, Athens, Greece
[5] Dept Cardiol, Ascardio, Barquisimeto, Venezuela
[6] Cardiovasc Ctr Bethanien, Dept Cardiol, Frankfurt, Germany
[7] Univ Milan, Dept Cardiol, Milan, Italy
[8] Christian Albrechts Univ Kiel Klinikum, Dept Pediat Cardiol, Dept Cardiol, Kiel, Germany
[9] German Heart Inst, Dept Congenital Heart Dis, Berlin, Germany
关键词
heart septal defects; catheterization; shunts;
D O I
10.1002/ccd.10406
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter closure of perimembranous ventricular septal defects with coils or devices designed to close other lesions may be complicated by embolization or aortic insufficiency. A new asymmetric Amplatzer perimembranous ventricular septal occluder and delivery system was specifically designed for perimembranous defects. This report describes the first use of this device in 27 patients. Implantation was successful in 25 (93%), with 1 removed for device-related aortic insufficiency and inability to position the delivery sheath in another. Device orientation was excellent when the device was initially advanced through a standard delivery sheath positioned in the left ventricular apex. Twenty-three had complete occlusion within 1 week (92%), with a tiny (<2 mm) residual shunt in the other two. In the 25 subjects with the device left in place, device-related aortic or tricuspid insufficiency, arrhythmias, and embolization were not observed. These excellent acute results need to be confirmed by long-term follow-up.
引用
收藏
页码:238 / 245
页数:8
相关论文
共 6 条
[1]  
Gu XP, 2000, CATHETER CARDIO INTE, V50, P502, DOI 10.1002/1522-726X(200008)50:4<502::AID-CCD29>3.3.CO
[2]  
2-#
[3]   TRANSCATHETER CLOSURE OF VENTRICULAR SEPTAL-DEFECTS [J].
LOCK, JE ;
BLOCK, PC ;
MCKAY, RG ;
BAIM, DS ;
KEANE, JF .
CIRCULATION, 1988, 78 (02) :361-368
[4]  
RIGBY ML, 1994, BRIT HEART J, V72, P368
[5]   Occlusion of congenital ventricular septal defects by the buttoned device [J].
Sideris, EB ;
Walsh, KP ;
Haddad, JL ;
Chen, CR ;
Ren, SG ;
Kulkarni, H .
HEART, 1997, 77 (03) :276-279
[6]   Perforation of the right aortic valve cusp: Complication of ventricular septal defect closure with a modified Rashkind umbrella [J].
Vogel, M ;
Rigby, ML ;
Shore, D .
PEDIATRIC CARDIOLOGY, 1996, 17 (06) :416-418