Automated detection of microaneurysms in digital red-free photographs: a diabetic retinopathy screening tool

被引:107
作者
Hipwell, JH [1 ]
Strachan, F [1 ]
Olson, JA [1 ]
McHardy, KC [1 ]
Sharp, PF [1 ]
Forrester, JV [1 ]
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, Aberdeen AB9 2ZD, Scotland
关键词
digital retinal photography; microaneurysms; image processing;
D O I
10.1046/j.1464-5491.2000.00338.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To develop a technique to detect microaneurysms automatically in 50 degrees digital red-free fundus photographs and evaluate its performance as a tool for screening diabetic patients for retinopathy, Methods Candidate microaneurysms are extracted, after the image has been modified to remove variations In background intensity, by algorithms that enhance small round features. Each microaneurysm candidate is then classified according to its intensity and size by the application of a sec of rules derived from a training set of 102 images. Results When 3783 individual images were analysed and the results compared with the opinion of a clinical research fellow examining the same images, the program achieved a sensitivity of 81% and a specificity of 93% for the detection of images containing microaneurysms, Nine hundred and twenty-five sets of 4 images per patient were then analysed and the total number of microaneurysms detected compared with the overall patient retinopathy grade derived by the clinician examining the same images. In this context, intended to mimic a screening situation, the program achieved a sensitivity of 85% and a specificity of 76% for the detection of patients with (any) retinopathy (positive predictive value 0.71, negative predictive value 0,88), Conclusions An automated technique was developed to detect retinopathy in digital red-free fundus images that can form part of a diabetic retinopathy screening programme. It is believed that it can perform a useful role in this context identifying images worthy of closer inspection or eliminating 50% or more of the screening population who have no retinopathy.
引用
收藏
页码:588 / 594
页数:7
相关论文
共 23 条
[1]  
ALDINGTON SJ, 1995, DIABETOLOGIA, V38, P437, DOI 10.1007/BF00410281
[2]  
[Anonymous], 1991, Ophthalmology, V98, P786
[3]  
*BRIT DIAB ASS, 1994, RET PHOT SCREEN DIAB
[4]   A fully automated comparative microaneurysm digital detection system [J].
Cree, MJ ;
Olson, JA ;
McHardy, KC ;
Sharp, PF ;
Forrester, JV .
EYE, 1997, 11 (5) :622-628
[5]  
EGE BM, 1997, DIABETIC MED, V14, P527
[6]  
Foulds W S, 1983, Health Bull (Edinb), V41, P318
[7]   Automatic detection of diabetic retinopathy using an artificial neural network: A screening tool [J].
Gardner, GG ;
Keating, D ;
Williamson, TH ;
Elliott, AT .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (11) :940-944
[8]   Identification of individual microaneurysms: A comparison between fluorescein angiograms and red-free and colour photographs [J].
Hellstedt, T ;
Vesti, E ;
Immonen, I .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1996, 234 :S13-S17
[9]  
HELLSTEDT T, 1994, ACTA OPHTHALMOL, V72, P352
[10]  
HELLSTEDT T, BR J OPHTHALMOL, V6, P135