Quantification of endogenous steroids in human urine by gas chromatography mass spectrometry using a surrogate analyte approach

被引:30
作者
Ahmadkhaniha, Reza [4 ,5 ]
Shafiee, Abbas [4 ,5 ]
Rastkari, Noushin [3 ]
Khoshayand, Mohammad Reza [2 ]
Kobarfard, Farzad [1 ]
机构
[1] Shahid Beheshti Univ, Sch Pharm, Dept Med Chem, Tehran, Iran
[2] Univ Tehran Med Sci, Fac Pharm, Dept Food & Drug Control, Tehran 14174, Iran
[3] Univ Tehran Med Sci, Environm Res Ctr, Tehran 14174, Iran
[4] Univ Tehran Med Sci, Fac Pharm, Dept Med Chem, Tehran 14174, Iran
[5] Univ Tehran Med Sci, Pharmaceut Sci Res Ctr, Tehran 14174, Iran
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 11-12期
基金
美国国家科学基金会;
关键词
Endogenous steroid; Surrogate analyse; Calibration curve; Urine; Gas chromatography mass spectrometry; BIOLOGICAL SAMPLES; METHOD VALIDATION; DOPING CONTROL; HUMAN-SERUM; EXTRACTION; CORTISOL; HORMONES; PLASMA; MATRIX; MEAT;
D O I
10.1016/j.jchromb.2010.01.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Providing "real blank sample" is a problem in determination of endogenous steroids in complex matrices. A new quantification strategy is proposed in the present study, which is based on using isotope-labeled steroids instead of natural steroids for constructing calibration line. This approach is called surrogate analyte and it is shown that its accuracy is better than some of the previously described methods at low concentrations and comparable to standard addition method at medium and high concentration levels. The method was fully validated to satisfy the ICH criteria and it was applied for determination of endogenous steroids in several urine samples. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:845 / 852
页数:8
相关论文
共 44 条
  • [1] Simple liquid chromatography method for the rapid simultaneous determination of prednisolone and cortisol in plasma and urine using hydrophilic lipophilic balanced solid phase extraction cartridges
    AbuRuz, S
    Millership, J
    Heaney, L
    McElnay, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (02): : 193 - 201
  • [2] Assessment of endogenous androgen levels in meat, liver and testis of Iranian native cross-breed male sheep and bull by gas chromatography-mass spectrometry
    Ahmadkhaniha, R.
    Kobarfard, F.
    Rastkari, N.
    Khoshayand, M. R.
    Amini, M.
    Shafiee, A.
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (04): : 453 - 465
  • [3] Accurate quantification of endogenous androgenic steroids in cattle's meat by gas chromatography mass spectrometry using a surrogate analyte approach
    Ahmadkhaniha, Reza
    Shafiee, Abbas
    Rastkari, Noushin
    Kobarfard, Farzad
    [J]. ANALYTICA CHIMICA ACTA, 2009, 631 (01) : 80 - 86
  • [5] Estimates of precision in a standard additions analysis
    Bruce, GR
    Gill, PS
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1999, 76 (06) : 805 - 807
  • [6] CURRELL G, 2000, ANAL INSTRUM, P193
  • [7] ISOTOPE-DILUTION MASS-SPECTROMETRY IN CLINICAL-CHEMISTRY
    DELEENHEER, AP
    LEFEVERE, MF
    LAMBERT, WE
    COLINET, ES
    [J]. ADVANCES IN CLINICAL CHEMISTRY, 1985, 24 : 111 - 161
  • [8] Garofolo F, 2004, ANALYTICAL METHOD VALIDATION AND INSTRUMENT PERFORMANCE VERIFICATION, P105, DOI 10.1002/0471463728.ch8
  • [9] GEYER H, 1995, RECENT ADV DOPING AN, V2, P199
  • [10] History of mass spectrometry at the Olympic Games
    Hemmersbach, Peter
    [J]. JOURNAL OF MASS SPECTROMETRY, 2008, 43 (07): : 839 - 853