Reproducibility of allergen, endotoxin and fungi measurements in the indoor environment

被引:94
作者
Heinrich, J
Hölscher, B
Douwes, J
Richter, K
Koch, A
Bischof, W
Fahlbusch, B
Kinne, RW
Wichmann, HE
机构
[1] GSF, Inst Epidemiol, Natl Res Ctr Environm & Hlth, D-85758 Neuherberg, Germany
[2] Univ Utrecht, Inst Risk Assessment Sci, Div Environm & Occupat Hlth, Utrecht, Netherlands
[3] Grosshansdorf Hosp, Ctr Pneumol & Thorac Surg, Hamburg, Germany
[4] Univ Jena, Dept Indoor Climatol, Erfurt, Germany
[5] Univ Jena, Inst Immunol, D-6900 Jena, Germany
[6] Univ Munich, Dept Epidemiol, Neuherberg, Germany
来源
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY | 2003年 / 13卷 / 02期
关键词
reproducibility; house dust mite; cat; allergen; endotoxin; house dust; fungi;
D O I
10.1038/sj.jea.7500267
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Measurements of biocontaminants in settled house dust once a year are commonly used to assess long-term exposure. To examine stability over time and seasonal variation, we measured concentrations of mite and cat allergens, endotoxin and mold spores in living room floor dust in 745 German homes collected twice a year in two different seasons. The study population consisted of adults and children living in five different areas in Germany. All dust samples were collected in a standardized manner from the living room floor and taken during the years 1995 to 1998. The median interval between the two dust samplings was approximately 7 months. Mite and cat allergens were measured in settled house dust by monoclonal antibodies, endotoxin by the limulus amebocyte lysate method, and total spore counts by cultural methods. Crude Pearson's correlation coefficients between log-transformed concentrations in the first and second dust samples ranged between 0.65 and 0.75 for allergens, 0.59 for endotoxin and only 0.06 for total spore counts. The strongest and most consistent seasonal effects were observed for fungi with highest levels in July-September. Cat allergen concentrations were found consistently to be increased in January-March. Mite allergens did not show a strong and consistent seasonal pattern. We conclude that repeated measurements of mite and cat allergens and endotoxin in settled house dust improve the estimate for annual mean concentrations. However, even a single observation of these biocontaminants may be a good proxy for a 1-year exposure since repeated measures were highly correlated. However, repeated measurements of fungi levels were only weakly correlated and thus repeated observations for assessment of annual means of total spore counts are needed.
引用
收藏
页码:152 / 160
页数:9
相关论文
共 39 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R
[2]   Predictors of high endotoxin concentrations in the settled dust of German homes [J].
Bischof, W ;
Koch, A ;
Gehring, U ;
Fahlbusch, B ;
Wichmann, HE ;
Heinrich, J .
INDOOR AIR, 2002, 12 (01) :2-9
[3]   THE EUROPEAN-COMMUNITY-RESPIRATORY-HEALTH-SURVEY [J].
BURNEY, PGJ ;
LUCZYNSKA, C ;
CHINN, S ;
JARVIS, D ;
VERMEIRE, P ;
DAHL, R ;
NIELSEN, N ;
MAGNUSSEN, H ;
WICHMANN, H ;
PAPAGEORGIOU, N ;
ANTO, J ;
CAPELASTEGUI, A ;
CASTILLO, J ;
MALDONADO, J ;
MORATALLA, J ;
QUIROS, R ;
BOUSQUET, J ;
NEUKIRCH, F ;
PIN, I ;
TAYTARD, A ;
TECULESCU, D ;
PRICHARD, J ;
BUGIANI, M ;
DEMARCO, R ;
CASCIO, VL ;
RIJCKEN, B ;
AVILA, R ;
LOUREIRO, C ;
MARQUES, A ;
BURR, M ;
HALL, R ;
HARRISON, B ;
STARK, J ;
FLOREY, C ;
POPP, W ;
GISLASON, T ;
GULSVIK, A ;
ACKERMANNLIEBRICH, U ;
LINDHOLM, N ;
BOMAN, G ;
ROSENHALL, L ;
AITKHALED, N ;
ABRAMSON, M ;
MANFREDA, J ;
CHOWGULE, R ;
CRANE, J ;
STEPANOV, I ;
BUIST, S .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (05) :954-960
[4]   HOUSE-DUST MITE ALLERGEN LEVELS IN 2 CITIES IN CANADA - EFFECTS OF SEASON, HUMIDITY, CITY AND HOME CHARACTERISTICS [J].
CHANYEUNG, M ;
BECKER, A ;
LAM, J ;
DIMICHWARD, H ;
FERGUSON, A ;
WARREN, P ;
SIMONS, E ;
BRODER, I ;
MANFREDA, J .
CLINICAL AND EXPERIMENTAL ALLERGY, 1995, 25 (03) :240-246
[5]   Fungal extracellular polysaccharides, β (1→3)-glucans and culturable fungi in repeated sampling of house dust [J].
Chew, GL ;
Douwes, J ;
Doekes, G ;
Higgins, KM ;
van Strien, R ;
Spithoven, J ;
Brunekreef, B .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2001, 11 (03) :171-178
[6]  
Diggle P. J., 2002, ANAL LONGITUDINAL DA
[7]   Does environmental endotoxin exposure prevent asthma? [J].
Douwes, J ;
Pearce, N ;
Heederik, D .
THORAX, 2002, 57 (01) :86-90
[8]   Fungal extracellular polysaccharides in house dust as a marker for exposure to fungi: Relations with culturable fungi, reported home dampness, and respiratory symptoms [J].
Douwes, J ;
van der Sluis, B ;
Doekes, G ;
van Leusden, F ;
Wijnands, L ;
van Strien, R ;
Verhoeff, A ;
Brunekreef, B .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (03) :494-500
[9]  
Efron B., 1993, INTRO BOOTSTRAP, V1st ed., DOI DOI 10.1201/9780429246593
[10]   Allergens in house-dust samples in Germany:: results of an East-West German comparison [J].
Fahlbusch, B ;
Heinrich, J ;
Gross, I ;
Jäger, L ;
Richter, K ;
Wichmann, HE .
ALLERGY, 1999, 54 (11) :1215-1222