Assessment and validation of a simple automated method for the detection of gait events and intervals

被引:181
作者
Ghoussayni, S
Stevens, C
Durham, S
Ewins, D
机构
[1] Univ Surrey, Ctr Biomed Engn, Guildford GU2 7TE, Surrey, England
[2] Queen Marys Hosp, Gait Lab, London, England
基金
英国工程与自然科学研究理事会;
关键词
kinematic gait event detection; temporal gait parameters; heel contact; toe off; heel toe intervals;
D O I
10.1016/j.gaitpost.2003.10.001
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A simple and rapid automatic method for detection of gait events at the foot could speed up and possibly increase the repeatability of gait analysis and evaluations of treatments for pathological gaits. The aim of this study was to compare and validate a kinematic-based algorithm used in the detection of four gait events, heel contact, heel rise, toe contact and toe off. Force platform data is often used to obtain start and end of contact phases, but not usually heel rise and toe contact events. For this purpose synchronised kinematic, kinetic and video data were captured from 12 healthy adult subjects walking both barefoot and shod at slow and normal self-selected speeds. The data were used to determine the gait events using three methods: force, visual inspection and algorithm methods. Ninety percent of all timings given by the algorithm were within one frame (16.7 ms) when compared to visual inspection. There were no statistically significant differences between the visual and algorithm timings. For both heel and toe contact the differences between the three methods were within 1.5 frames, whereas for heel rise and toe off the differences between the force on one side and the visual and algorithm on the other were higher and more varied (up to 175 ms). In addition, the algorithm method provided the duration of three intervals, heel contact to toe contact, toe contact to heel rise and heel rise to toe off, which are not readily available from force platform data. The ability to automatically and reliably detect the timings of these four gait events and three intervals using kinematic data alone is an asset to clinical gait analysis. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 11 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
GHOUSSAYNI S, 2001, P 7 VIENN INT WORKSH, P90
[3]   A simple method for determination of gait events [J].
Hansen, AH ;
Childress, DS ;
Meier, MR .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :135-138
[4]   Algorithms to determine event timing during normal walking using kinematic data [J].
Hreljac, A ;
Marshall, RN .
JOURNAL OF BIOMECHANICS, 2000, 33 (06) :783-786
[5]  
HYND D, 2000, J ENG MED, V214, pH193
[6]   Validity and reliability of a kinematic protocol for determining foot contact events [J].
Mickelborough, J ;
van der Linden, ML ;
Richards, J ;
Ennos, AR .
GAIT & POSTURE, 2000, 11 (01) :32-37
[7]  
PASSING H, 1983, J CLIN CHEM CLIN BIO, V21, P709
[8]   Limb locomotion - speed distribution analysis as a new method for stance phase detection [J].
Peham, C ;
Scheidl, M ;
Licka, T .
JOURNAL OF BIOMECHANICS, 1999, 32 (10) :1119-1124
[9]   KINEMATIC-BASED TECHNIQUE FOR EVENT TIME DETERMINATION DURING GAIT [J].
STANHOPE, SJ ;
KEPPLE, TM ;
MCGUIRE, DA ;
ROMAN, NL .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (04) :355-360
[10]  
STEVENS C, 2001, P 6 ANN C INT FUNCT, P85