Dynamic three-dimensional MR renography for the measurement of single kidney function: Initial experience

被引:104
作者
Lee, VS [1 ]
Rusinek, H [1 ]
Noz, ME [1 ]
Lee, P [1 ]
Raghavan, M [1 ]
Kramer, EL [1 ]
机构
[1] NYU, Med Ctr, Dept Radiol MRI, New York, NY 10016 USA
关键词
kidney; function; perfusion; magnetic resonance (MR); contrast enhancement; perfusion study;
D O I
10.1148/radiol.2271020383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A three-dimensional magnetic resonance (MR) renographic method to measure single kidney glomerular filtration rate (GFR) and split renal function was developed that is based on renal signal intensity measurements during 2-3 minutes after intravenous injection of a low dose (2 mL or 0.01 mmol/kg) of gadopentetate dimeglumine. In nine subjects, single kidney MR GFR indices correlated well with technetium (Tc-99m) diethylenetriaminepentaacetic acid (DTPA) clearance (r = 0.7-0.8) for GFR values of 7-48 mL/min. MR right kidney split renal function values (range, 32%-59%) also correlated well with Tc-99m-DTPA radionuclide measurements (r = 0.76); differences between the two methods averaged 0.8% +/- 8. MR renography was performed along with contrast material-enhanced MR imaging of the kidneys and renal arteries and added 8 minutes or less to the total examination time. (C) RSNA, 2003.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 32 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Boykov Y, 2001, P 4 INT C MED IM COM, P1058
[3]   USE OF GD-DTPA AND FAST GRADIENT-ECHO AND SPIN-ECHO MR IMAGING TO DEMONSTRATE RENAL-FUNCTION IN THE RABBIT [J].
CARVLIN, MJ ;
ARGER, PH ;
KUNDEL, HL ;
AXEL, L ;
DOUGHERTY, L ;
KASSAB, EA ;
MOORE, B .
RADIOLOGY, 1989, 170 (03) :705-711
[4]   HYDRATED CLEARANCE OF GADOLINIUM-DTPA AS A MEASUREMENT OF GLOMERULAR-FILTRATION RATE [J].
CHOYKE, PL ;
AUSTIN, HA ;
FRANK, JA ;
GIRTON, ME ;
DIGGS, RL ;
DWYER, AJ ;
MILLER, L ;
NUSSENBLATT, R ;
MCFARLAND, H ;
SIMON, T .
KIDNEY INTERNATIONAL, 1992, 41 (06) :1595-1598
[5]   Noninvasive measurement of extraction fraction and single-kidney glomerular filtration rate with MR imaging in swine with surgically created renal artery stenoses [J].
Coulam, CH ;
Lee, JH ;
Wedding, KL ;
Spielman, DM ;
Pelc, NJ ;
Kee, ST ;
Hill, BB ;
Bouley, DM ;
Derby, GC ;
Myers, BD ;
Sawyer-Glover, AM ;
Sommer, FG .
RADIOLOGY, 2002, 223 (01) :76-82
[6]   NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING [J].
DUMOULIN, CL ;
BUONOCORE, MH ;
OPSAHL, LR ;
KATZBERG, RW ;
DARROW, RD ;
MORRIS, TW ;
BATEY, C .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :370-378
[7]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[8]   GADOPENTETATE DIMEGLUMINE AS A MARKER OF RENAL-FUNCTION - MAGNETIC-RESONANCE-IMAGING TO GLOMERULAR-FILTRATION RATES [J].
FRANK, JA ;
CHOYKE, PL ;
AUSTIN, HA ;
GIRTON, ME ;
WEISS, G .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S134-S136
[9]  
FRANK JA, 1991, INVEST RADIOL S1, V26, pS137
[10]   Evaluation of glomerular function in individual kidneys using dynamic magnetic resonance imaging [J].
Fukuda, Y ;
Watanabe, H ;
Tomita, T ;
Katayama, H ;
Miyano, T ;
Yabuta, K .
PEDIATRIC RADIOLOGY, 1996, 26 (05) :324-328