Bachmann's Bundle versus right atrial appendage capture

被引:3
作者
Bailin, SJ
Machado, C
Nsah, E
Worley, S
Kremers, M
Bailey, JR
Hildebrand, L
机构
[1] Iowa Heart Ctr, Des Moines, IA 50314 USA
[2] Providence Hosp & Med Ctr, Southfield, MI USA
[3] Peninsula Reg Med Ctr, Salisbury, MD USA
[4] Lancaster Heart Fdn, Lancaster, PA USA
[5] Mid Carolina Cardiol, Charlotte, NC USA
[6] St Jude Med, Sylmar, CA USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 01期
关键词
Bachmann's Bundle; Autocapture; right atrial appendage;
D O I
10.1046/j.1460-9592.2003.00029.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The tissue in the high intraatrial septum in the region of Bachmann's Bundle (BB) exhibits electrophysiological properties that differ from the right atrial appendage (RAA). As BB pacing emerges as an alternative to RAA pacing, the feasibility of using automatic capture recognition technology in this location should be examined. At implant, active-fixation leads were consecutively placed in the RAA, then the BB in 18 patients (55.5 % men, mean age 77.1 +/- 9.1). There was no significant difference between BB and RAA in the average capture threshold (1.12 vs 1.77 V, P = 0.09), sensing threshold (3.85 vs 3.69 m V, P = 0.84), impedance (508 vs 529 Ohms, P = 0.64), evoked response (1.78 vs 1.67 mV, P = 0.83), and polarization (0.41 vs 0.46 mV, P = 0.84) between. The difference in tissue characteristics was not associated with a different evoked response measured by the ventricular capture recognition algorithm. Based on the analogous evoked response and polarization values, capture recognition technology designed for the atrium will most likely be applicable at both pacing sites.
引用
收藏
页码:264 / 267
页数:4
相关论文
共 5 条
[1]   Prevention of chronic atrial fibrillation by pacing in the region of Bachmann's bundle: Results of a multicenter randomized trial [J].
Bailin, SJ ;
Adler, S ;
Giudici, M .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (08) :912-917
[2]  
Chisner MB, 2001, J AM COLL CARDIOL, V37, p117A
[3]   Atrial septal pacing to synchronize atrial depolarization in patients with delayed interatrial conduction [J].
Katsivas, A ;
Manolis, AG ;
Lazaris, E ;
Vassilopoulos, C ;
Louvros, N .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2220-2225
[4]   A cardiac evoked response algorithm providing threshold tracking: A North American multicenter study [J].
Lau, C ;
Cameron, DA ;
Nishimura, SC ;
Ahern, T ;
Freedman, RA ;
Ellenbogen, K ;
Greenberg, S ;
Baker, J ;
Meacham, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (06) :953-959
[5]   USE OF BACHMANN BUNDLE FOR BIPOLAR ATRIAL-PACING [J].
SAVITT, MA ;
RANKIN, JS .
ANNALS OF THORACIC SURGERY, 1993, 56 (01) :183-184