The mature of flow in the systemic venous pathway measured by magnetic resonance blood tagging in patients having the Fontan operation

被引:79
作者
Fogel, MA
Weinberg, PM
Hoydu, A
Hubbard, A
Rychik, J
Jacobs, M
Fellows, KE
Haselgrove, J
机构
[1] Univ Penn, Sch Med, Dept Pediat, Div Cardiol,Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Surg, Div Cardiovasc Surg,Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
[3] Univ Penn, Sch Med, Dept Pediat, Philadelphia, PA 19104 USA
[4] Univ Penn, Sch Med, Dept Surg, Philadelphia, PA 19104 USA
[5] Univ Penn, Sch Med, Dept Radiol, Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/S0022-5223(97)70017-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Our objectives were twofold: (1) to determine cardiac and respiratory dependency of systemic venous pathway how of patients having the Fontan operation with a total cavopulmonary connection and (2) to describe the velocity profile. Systemic venous pathway flow is hypothesized to be mostly respiratory dependent, to be laminar, and to have a smooth velocity profile. Methods: Twenty-two patients having the Fontan operation (aged 8.6 +/- 4.7 years) underwent magnetic resonance blood tagging (bolus tagging). Systemic venous pathway spin-echo images parallel to the blood Bow were used as a localizer. A saturation pulse labeled the blood, and a cine image was acquired at the inferior and superior venae cavae and midportion of the baffle in the systemic venous pathway, triggered to the electrocardiogram and gated to both end-expiration and end-inspiration. Repetition time was 50 msec. Results: Flow in the systemic venous pathway was laminar throughout its course and was found to be phasic to both cardiac and respiratory cycles. Approximately 70% of how was cardiac dependent, and the rest was respiratory. Highest flow occurred near end-systole and early diastole and in inspiration, Lowest flow occurred in diastasis. Velocity was highest and flow least "pluglike" in the mid-baffle area during cardiac or respiratory imaging (45 +/- 17 and 32 +/- 11 cm/sec, respectively). Conclusion: A substantial amount of pulmonary blood flow in patients who have undergone a total cavopulmonary connection type of Fontan operation has a cardiac component. Furthermore, we confirm that this flow is laminar but nonuniform across the systemic venous pathway. Highest hows occurred near end-systole and early diastole, as well as in inspiration, and the lon est flow occurred in diastasis. This information mag help in designing the systemic venous pathway and optimizing medical management.
引用
收藏
页码:1032 / 1041
页数:10
相关论文
共 30 条
[1]  
BERNE RM, 1992, CARDIOVASCULAR PHYSL, P73
[2]  
Bird R.B., 1960, INT J TRANSP PHENOM, V11, P5
[3]  
Cape Edward G., 1993, P24
[4]  
CHIN AJ, 1994, NONINVASIVE IMAGING, P349
[5]  
Chiu I S, 1991, J Formos Med Assoc, V90, P347
[6]  
DELEVAL MR, 1988, J THORAC CARDIOV SUR, V96, P682
[7]   SYSTEMIC VENOUS AND PULMONARY ARTERIAL FLOW PATTERNS AFTER FONTAN PROCEDURE FOR TRICUSPID ATRESIA OR SINGLE VENTRICLE [J].
DISESSA, TG ;
CHILD, JS ;
PERLOFF, JK ;
WU, L ;
WILLIAMS, RG ;
LAKS, H ;
FRIEDMAN, WF .
CIRCULATION, 1984, 70 (05) :898-902
[8]   QUANTIFICATION OF BLOOD-FLOW WITH DYNAMIC MR IMAGING AND PRESATURATION BOLUS TRACKING [J].
EDELMAN, RR ;
MATTLE, HP ;
KLEEFIELD, J ;
SILVER, MS .
RADIOLOGY, 1989, 171 (02) :551-556
[9]   IMAGING OF PULMONARY VENOUS PATHWAY OBSTRUCTION IN PATIENTS AFTER THE MODIFIED FONTAN PROCEDURE [J].
FOGEL, MA ;
CHIN, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (01) :181-190
[10]   OUTCOME AFTER A PERFECT FONTAN OPERATION [J].
FONTAN, F ;
KIRKLIN, JW ;
FERNANDEZ, G ;
COSTA, F ;
NAFTEL, DC ;
TRITTO, F ;
BLACKSTONE, EH .
CIRCULATION, 1990, 81 (05) :1520-1536