Biomechanical investigation of the primary stability of intramedullary compression nails in the proximal tibia: experimental study using interlocking screws in cryopreserved human tibias

被引:12
作者
Gollwitzer, H
Karampour, K
Hauschild, M
Diehl, P
Busch, R
Mittelmeier, W
机构
[1] Tech Univ Munich, Klin & Poliklin Othopadie & Sportorthopadie, D-81675 Munich, Germany
[2] Berufsgenossenschaftl Unifallklin Murnau, Abt Unfallchirurg, D-82418 Murnau, Germany
[3] Tech Univ Munich, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
关键词
biomechanics; interlocking nail; compression; tibia; bone density;
D O I
10.1007/s00776-003-0731-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The biomechanical properties of the proximal tibia with respect to the application of compressible intramedullary nails were examined in a biomechanical model using human cadaver bones. A reference level was examined histomorphometrically in 24 cryopreserved human tibias. Three series of single or double interlocking fixations were tested at various distances from the tibial plateau. Yield strength, rigidity of the bone stock, maximum load, and compression distances were determined during axial strain. The positioning of the interlocking screws had a considerable influence on maximum load and deformation behavior of the bone. The double interlocking tended to display the best stability in the bone stock, and the distally placed single interlocking method was next best. Failure of the bone stock was observed with significant variations in compression distance and load, with great variations between individual specimens. The stability of the bone stock could not be accurately predicted using such clinical parameters as the patient's age, bone dimensions, radiographic parameters, and bone density. When using a tibial compression nail, the proximal interlocking screw should be placed relatively distal to achieve adequate support. It is possible to apply compression with one proximal interlocking screw under low preload or, preferably, with two interlocking screws.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 18 条
[1]
Bircher H, 1886, ARCH KLIN CHIR, V34, P410
[2]
FRACTURES OF THE SHAFT OF THE FEMUR [J].
BUCHOLZ, RW ;
JONES, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (10) :1561-1566
[3]
Interlocking compression nailing: a report on 402 applications [J].
Gonschorek, O ;
Hofmann, GO ;
Buhren, V .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1998, 117 (08) :430-437
[4]
THE INFLUENCE OF INDUCED MICROMOVEMENT UPON THE HEALING OF EXPERIMENTAL TIBIAL FRACTURES [J].
GOODSHIP, AE ;
KENWRIGHT, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (04) :650-655
[5]
Contribution of trabecular and cortical components to the mechanical properties of bone and their regulating parameters [J].
Ito, M ;
Nishida, A ;
Koga, A ;
Ikeda, S ;
Shiraishi, A ;
Uetani, M ;
Hayashi, K ;
Nakamura, T .
BONE, 2002, 31 (03) :351-358
[6]
Kaessmann H J, 1969, Zentralbl Chir, V94, P496
[7]
MITTELMEIER H, 1975, MED ORTHOP TECH, V95, P49
[8]
MITTELMEIER H, 1989, HEFTE UNFALLHEILKD, V207, P305
[9]
Mittelmeier W, 2001, MATERIALWISS WERKST, V32, P897
[10]
MITTELMEIER W, 1999, OSTEOLOGIE, V8, P119