A technique to assess aortic distensibility and compliance in anesthetized and awake rats

被引:21
作者
VanGorp, A
Schenau, DSV
Willigers, J
Hoeks, APG
DeMey, JGR
Boudier, HAJS
Reneman, RS
机构
[1] UNIV LIMBURG, CARDIOVASC RES INST MAASTRICHT, DEPT PHYSIOL, 6200 MD MAASTRICHT, NETHERLANDS
[2] UNIV LIMBURG, CARDIOVASC RES INST MAASTRICHT, DEPT PHARMACOL, 6200 MD MAASTRICHT, NETHERLANDS
[3] UNIV LIMBURG, CARDIOVASC RES INST MAASTRICHT, DEPT BIOPHYS, 6200 MD MAASTRICHT, NETHERLANDS
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1996年 / 270卷 / 02期
关键词
aortic compliance; ultrasound wall tracking; B-mode imager; pulse pressure; aortic diameter; aortic wall displacement; coefficient of variation; intra-session; inter-session;
D O I
10.1152/ajpheart.1996.270.2.H780
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A noninvasive ultrasonic technique, based on tracking arterial wall displacements with a vessel wall-tracking device attached to a conventional B-mode imager, to assess end-diastolic aortic diameter (d) and aortic diameter changes during the cardiac cycle (Delta d) in anesthetized and awake rats is presented. From these parameters and invasively measured aortic pulse pressure (Delta P), aortic distensibility and compliance, the relative and absolute increases in lumen cross-sectional area for a given increase in Delta P, respectively, can be calculated. d, Delta d, and Delta P could be determined with good intra-session (variations per day) and inter-session (variations between days) coefficients of variation (CV). The CVs for Delta d were smaller in awake (4.6-6.0%) than in anesthetized rats (7.9-11.0%), probably due to variations in Delta P during anesthesia (CV: 9.0-12.3%). The CVs for d in awake (3.3-6.5%) and anesthetized rats (2.6-5.0%) were comparable. In awake rats the CV for Delta d, but not for d, increased after implantation of the aortic catheter. It is concluded that d, Delta d, and Delta P ofthe aorta can be reliably measured noninvasively in anesthetized and awake rats, allowing the in vivo assessment of aortic distensibility and compliance. The technique is sensitive enough to detect effects of agents on aortic wall properties.
引用
收藏
页码:H780 / H786
页数:7
相关论文
共 20 条
[1]   DIAMETER OF INTACT CAROTID ARTERY IN MAN AND ITS CHANGE WITH PULSE PRESSURE [J].
ARNDT, JO ;
KLAUSKE, J ;
MERSCH, F .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1968, 301 (03) :230-&
[2]   MECHANICAL-PROPERTIES OF ARTERIES [J].
DOBRIN, PB .
PHYSIOLOGICAL REVIEWS, 1978, 58 (02) :397-460
[3]   ELASTICITY OF CANINE AND HUMAN CORONARY-ARTERIES WITH REFERENCE TO POSTMORTEM CHANGES [J].
GOW, BS ;
HADFIELD, CD .
CIRCULATION RESEARCH, 1979, 45 (05) :588-594
[4]   A DIGITAL TECHNIQUE FOR TRACKING MOVING INTERFACES [J].
GROVES, DH ;
POWALOWSKI, T ;
WHITE, DN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (02) :185-&
[5]  
HAYOZ D, 1992, J HYPERTENS S5, V10, pS95
[6]   TRANS-CUTANEOUS DETECTION OF RELATIVE CHANGES IN ARTERY DIAMETER [J].
HOEKS, APG ;
RUISSEN, CJ ;
HICK, P ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (01) :51-59
[7]   ASSESSMENT OF THE DISTENSIBILITY OF SUPERFICIAL ARTERIES [J].
HOEKS, APG ;
BRANDS, PJ ;
SMEETS, FAM ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (02) :121-128
[8]   COMPARISON OF THE PERFORMANCE OF THE RF CROSS-CORRELATION AND DOPPLER AUTOCORRELATION TECHNIQUE TO ESTIMATE THE MEAN VELOCITY OF SIMULATED ULTRASOUND SIGNALS [J].
HOEKS, APG ;
ARTS, TGJ ;
BRANDS, PJ ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :727-740
[9]  
HOEKS APG, 1993, ARTERIAL SYSTEM HYPE, P119
[10]   PHASE-LOCKED ECHO TRACKING SYSTEM FOR RECORDING ARTERIAL DIAMETER CHANGES IN-VIVO [J].
HOKANSON, DE ;
STRANDNESS, DE ;
SUMNER, DS ;
MOZERSKY, DJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 32 (05) :728-+