Evaluation of GHb assays in France by national quality control surveys

被引:29
作者
Gillery, P
Dumont, G
Vassault, A
机构
[1] CHU Reims, Hop Robert Debre, Lab Cent Biochim, F-51092 Reims, France
[2] Hop Necker Enfants Malad, Lab Biochem A, Paris, France
[3] Hop Necker Enfants Malad, Soc Francaise Biol Clin, Paris, France
关键词
D O I
10.2337/diacare.21.2.265
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To evaluate the state of the art concerning GHb assays through analysis of a large-scale quality control survey and to compare the results with those of previous surveys RESEARCH DESIGN AND METHODS - A lyophilized hemolyzate prepared from human erythrocytes containing a physiological HbA(1c) level (5.5%) was sent to 3,500 French laboratories in February of 1995 and assayed as a patient's sample under routine conditions. Distribution of values was analyzed from the reported results for each method. The results were compared with the assigned value (acceptable range: +/-20%) and with the upper value of the reference range currently used. RESULTS - Results were obtained from 2,674 laboratories, among which 39% used cation-exchange chromatography methods, 37.5% affinity chromatography, 16% immunological methods, and 7.5% electrophoresis. The number of laboratories using immunological methods increased from 100 to 400 between 1993 and 1995. The overall interlaboratory coefficient of variation (CV) was 20.2%, with within-method CVs ranging between 3.2 and 29.5%. Method-to-method accuracy varied dramatically, with mean HbA(1c) values ranging from 4.4 to 8.2%. Results from 75% of the laboratories were comprised in the acceptable range; 88% of them reported a value within the normal range of the method used. CONCLUSIONS - The interlaboratory variability of results illustrates the difficulties encountered by diabetologists in the follow-up of diabetic patients using results obtained from different laboratories. It demonstrates the usefulness of the internationally developed standardization process of GHb measurements and points out the need for laboratories to fulfill good practices.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 27 条
[1]   OBSERVATIONS ON THE CHROMATOGRAPHIC HETEROGENEITY OF NORMAL ADULT AND FETAL HUMAN HEMOGLOBIN - A STUDY OF THE EFFECTS OF CRYSTALLIZATION AND CHROMATOGRAPHY ON THE HETEROGENEITY AND ISOLEUCINE CONTENT [J].
ALLEN, DW ;
SCHROEDER, WA ;
BALOG, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1958, 80 (07) :1628-1634
[2]  
American Diabetes Association, 1995, DIABETES CARE, V18, P8
[3]  
ANTSIFEROV M, 1993, DIABETIC MED, V10, P990
[4]   STRUCTURE OF HEMOGLOBIN AIC - NATURE OF N-TERMINAL BETA CHAIN BLOCKING GROUP [J].
BOOKCHIN, RM ;
GALLOP, PM .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1968, 32 (01) :86-&
[5]   Interlaboratory variation of GHb assays in Victoria, Australia [J].
Gilbert, RE ;
Goodall, I ;
Young, V ;
Jerums, G .
DIABETES CARE, 1996, 19 (07) :730-734
[6]  
GILLERY P, 1995, CLIN CHEM, V41, P1644
[7]  
GILLERY P, 1994, ANN BIOL CLIN-PARIS, V52, P157
[8]  
GILLERY P, 1991, ANN CONTROLE QUAL NA, V8, P32
[9]  
GILLERY P, 1996, ANN CONTROLE QUAL NA, P9
[10]  
GILLERY P, 1993, ANN CONTROLE QUAL NA, V13, P11