Evaluation of perchlorate tolerant photo-cured calcium selective electrodes for use in flow injection potentiometry

被引:12
作者
DiBenedetto, LT [1 ]
Dimitrakopoulos, T [1 ]
Farrell, JR [1 ]
Iles, PJ [1 ]
机构
[1] ROYAL MELBOURNE INST TECHNOL,DEPT APPL CHEM,BUNDOORA,VIC 3038,AUSTRALIA
基金
澳大利亚研究理事会;
关键词
calcium selective electrodes; flow injection potentiometry; perchlorate tolerance; photo-cured membranes;
D O I
10.1016/S0039-9140(96)02057-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A photo-cured membrane selective to calcium, based on the calcium bis [4-(1',1',3',3'-tetramethylbutyl)phenyl]phosphate ionophore and incorporating the lipophilic additive, potassium tetraki(4-chlorophenyl)borate: that can tolerate up to 200 nM perchlorate ionic background in the flow injection potentiometry mode has been previously reported (T. Dimitrakopoulos, J.R. Farrell and P.J. Ives, Electroanalysis, 8 (1996) 391). Improvements in the electrode slope and sensitivity of the previously described photo-cured calcium membrane-based electrode were achieved when anhydrous calcium chloride salt was dissolved into the pre-cured membrane composition and then photo-cured, Similar to the previously reported photo-cured calcium ion-selective electrode (ISE), the improved photo-cured calcium ISE can measure calcium in a high perchlorate background in the flow injection potentiometric mode. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 19 条
[1]   ION SENSOR WITH PHOTOCURABLE POLYURETHANE POLYMER MEMBRANE [J].
BRATOV, A ;
ABRAMOVA, N ;
MUNOZ, J ;
DOMINGUEZ, C ;
ALEGRET, S ;
BARTROLI, J .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1994, 141 (09) :L111-L112
[2]   PHOTOCURABLE POLYMER MATRICES FOR POTASSIUM-SENSITIVE ION-SELECTIVE ELECTRODE MEMBRANES [J].
BRATOV, A ;
ABRAMOVA, N ;
MUNOZ, J ;
DOMINGUEZ, C ;
ALEGRET, S ;
BARTROLI, J .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3589-3595
[3]   PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .2. A CALCIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1985, 177 :239-242
[4]   PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .3. A POTASSIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1988, 204 (1-2) :329-332
[5]   PHOTOCURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES [J].
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :403-406
[6]  
CATTRALL RW, 1984, ION SEL ELECTRODE R, V6, P125
[7]   SOME ALKYLPHOSPHORIC ACID-ESTERS FOR USE IN COATED-WIRE CALCIUM-SELECTIVE ELECTRODES .3. STRUCTURAL CHARACTERISTICS OF CALCIUM DI(OCTYLPHENYL)PHOSPHATE [J].
CATTRALL, RW ;
NEWLANDS, MJ ;
MACKAY, MF .
ANALYTICA CHIMICA ACTA, 1983, 155 (DEC) :235-242
[8]  
DELMUNDO FR, 1908, ELECTROANAL, V1, P179
[9]  
DIBENEDETTO LT, 1996, IN PRESS ELECTROANAL
[10]  
DIMITRAKOPOULOS JR, 1996, ANAL CHIM ACTA, V335, P111