Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors

被引:90
作者
Jung, SK
Wilson, GS
机构
[1] UNIV KANSAS,DEPT CHEM,LAWRENCE,KS 66045
[2] UNIV KANSAS,CTR NEUROSCI & IMMUNOL RES,LAWRENCE,KS 66045
关键词
D O I
10.1021/ac950424p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An oxidase-based glucose sensor has been developed that uses a mercaptosilane-modified platinum electrode to achieve selectivity of electrochemical interferants. A platinum-iridium (9:1) wire (0.178 mm o.d., sensing area of 1.12 mm(2)) is modified with (3-mercaptopropyl)trimethoxysilane. The modified sensors show excellent operational stability for more than 5 days. Glucose oxidase is immobilized on the modified surface (i) by using 3-maleimidopropionic acid as a linker or (ii) by cross-linking with bovine serum albumin using glutaraldehyde. Sensitivities in the range of 9.97 nA/mM glucose are observed when the enzyme is immobilized by method ii, Lower sensitivities (1.13 x 10(-1) nA/mM glucose) are observed when immobilization method i is employed. In terms of linear response range, the sensor enzyme-immobilized by method i is superior to that immobilized by method ii. The linearity is improved upon coating the enzyme layer with polyurethane, The sensor immobilized by method ii and coated with polyurethane exhibits a linear range to 15 mM glucose and excellent selectivity to glucose (0.47 nA/mM) against interferants such as ascorbic acid, uric acid, and acetaminophen.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 30 条
  • [1] AMINE A, 1989, ANAL LETT, V22, P2403
  • [2] FORMATION OF MONOLAYER FILMS BY THE SPONTANEOUS ASSEMBLY OF ORGANIC THIOLS FROM SOLUTION ONTO GOLD
    BAIN, CD
    TROUGHTON, EB
    TAO, YT
    EVALL, J
    WHITESIDES, GM
    NUZZO, RG
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (01) : 321 - 335
  • [3] ELECTROCHEMISTRY AT OMEGA-HYDROXY THIOL COATED ELECTRODES .3. VOLTAGE INDEPENDENCE OF THE ELECTRON-TUNNELING BARRIER AND MEASUREMENTS OF REDOX KINETICS AT LARGE OVERPOTENTIALS
    BECKA, AM
    MILLER, CJ
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (06) : 2657 - 2668
  • [4] IMMOBILIZATION OF BETA-GALACTOSIDASE AND OTHER ENZYMES ONTO PARA-AMINO-CARBANILATED CELLULOSE DERIVATIVES
    BEDDOWS, CG
    MIRAUER, RA
    GUTHRIE, JT
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1980, 22 (02) : 311 - 321
  • [5] BEVERETT WR, 1995, ANAL CHEM, V67, P292
  • [6] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696
  • [7] SUPERLATTICE STRUCTURE AT THE SURFACE OF A MONOLAYER OF OCTADECANETHIOL SELF-ASSEMBLED ON AU(111)
    CAMILLONE, N
    CHIDSEY, CED
    LIU, GY
    SCOLES, G
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1993, 98 (04) : 3503 - 3511
  • [8] SELECTIVITY AND SENSITIVITY OF SELF-ASSEMBLED THIOCTIC ACID ELECTRODES
    CHENG, Q
    BRAJTERTOTH, A
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1998 - 2000
  • [9] MODIFICATION OF ELECTRODE SURFACES WITH OXIDIZED PHENOLS TO CONFER SELECTIVITY TO AMPEROMETRIC BIOSENSORS FOR GLUCOSE DETERMINATION
    CHRISTIE, IM
    VADGAMA, P
    LLOYD, S
    [J]. ANALYTICA CHIMICA ACTA, 1993, 274 (02) : 191 - 199
  • [10] SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS
    DAVE, BC
    DUNN, B
    VALENTINE, JS
    ZINK, JI
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (22) : A1120 - A1127