Fault location based on single terminal travelling wave analysis in radial distribution network

被引:62
作者
Liang Rui [1 ]
Fu Guoqing [1 ]
Zhu Xueyuan [1 ]
Xue Xue [1 ]
机构
[1] China Univ Min & Technol, Sch Informat & Elect Engn, Xuzhou 221008, Jiangsu, Peoples R China
基金
中国博士后科学基金;
关键词
Fault location; Traveling wave velocity; Wave fronts recognition; Wavelet transform; MODEL;
D O I
10.1016/j.ijepes.2014.10.026
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
Fault location remains a challenging problem in order to restore power supply rapidly. In this paper, a novel single-terminal traveling wave fault location procedure is proposed in a radial distribution network. Firstly, the propagating speed of zero mode traveling wave is determined by BP neutral network method. Then the preliminary estimation of fault distance is calculated based on the difference of velocities by discriminating the accurate timestamps of initial zero and aerial mode wave fronts. With this preliminary fault distance, the exact arrival timestamps of reflected wave fronts from fault position and far terminal end can be successful yielded. Finally, depended on mathematical relation of selected pairs-timestamps, the fault distance can be calculated precisely. Simulations have performed in PSCAD/EMTDC and the results show the accuracy and validity of procedures proposed above. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 21 条
[1]
Accurate fault location technique for distribution system using fault-generated high-frequency transient voltage signals [J].
Bo, ZQ ;
Weller, G ;
Redfern, MA .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1999, 146 (01) :73-79
[2]
Integrated Use of Time-Frequency Wavelet Decompositions for Fault Location in Distribution Networks: Theory and Experimental Validation [J].
Borghetti, A. ;
Bosetti, M. ;
Nucci, C. A. ;
Paolone, M. ;
Abur, A. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :3139-3146
[3]
Continuous-wavelet transform for fault location in distribution power networks: Definition of mother wavelets inferred from fault originated transients [J].
Borghetti, Alberto ;
Bosetti, Mauro ;
Di Silvestro, Mauro ;
Nucci, Carlo Alberto ;
Paolone, Mario .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) :380-388
[4]
Chen Z, 2005, IEEE T POWER SYST, V15, P370
[5]
Coser J, 2007, IEEE INT C INT SYST
[6]
Danda M, 2009, Power system protection and control, V37, P55
[7]
Using Modal Analysis to Estimate Received Signal Levels for a Power-Line Carrier Channel on a 500-kV Transmission Line [J].
Franklin, Gregory A. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) :2446-2454
[8]
Gilany M, 2004, IEEE T POWER DELIVER, V22, P4
[9]
Best ANN structures for fault location in single-and double-circuit transmission lines [J].
Gracia, J ;
Mazón, AJ ;
Zamora, I .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (04) :2389-2395
[10]
Huang Xiong, 2004, POWER SYST TECHNOL, V28, P4