A testing and HVAC design methodology for air-to-air heat pipe heat exchangers

被引:14
作者
Guo, PB [1 ]
Ciepliski, DL [1 ]
Besant, RW [1 ]
机构
[1] Univ Saskatchewan, Dept Mech Engn, Saskatoon, SK S7N 0W0, Canada
来源
HVAC&R RESEARCH | 1998年 / 4卷 / 01期
关键词
D O I
10.1080/10789669.1998.10391388
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-to-air heat pipe hear exchangers were tested wing ASHRAE Standard 84-1991 as a guide. Some changes are introduced for the test facility and methods of calculating effectiveness. ASME PTC 19.1-1985 is used as a guide for uncertainty analysis. Tests were done for a range of mass flux [1.574 to 2.912 kg/(m(2).s)], ratios of mass flow rates (0.6 to 1.85), supply air temperatures (-10 degrees C to 40 degrees C), and heat exchanger tilt angles (-8.9 degrees to 11.2 degrees). Because humidity changes in the exhaust and supply air streams were negligible, only the effectiveness of sensible and of total energy was considered. Measured and calculated results show significant variations in the effectiveness of sensible and of total energy, and uncertainties with each independent variable. For balanced exhaust and supply flow rates at -10 degrees C supply air temperature and 1.574 kg/(m(2).s) mass flux, the measured effectiveness for sensible and total energy was calculated to be 0.48 and 0.44, respectively, with uncertainties of 0.057 and 0.052. These measurements decreased to 0.42 and 0.37, with uncertainties of 0.016 and 0.018 for a mass flux of 2.912 kg/(m(2).s). Because water vapor condensation effects were small or negligible, the difference between the effectiveness for the sensible and total energy was within the overlapping uncertainty range of each. Based on counterflow heat exchanger theory and convective heat transfer equations, expressions are presented to extrapolate the effectiveness data between and beyond the measured data points. These effectiveness equations, which represent the variation in effectiveness with several independent operating variables, are used for HVAC design that is aimed at achieving minimum life-cycle costs.
引用
收藏
页码:3 / 26
页数:24
相关论文
共 20 条
[1]  
American Society of Heating Refrigeration and Air-Conditioning Engineers, 2017, ASHRAE HDB FUND
[2]  
*ANSI ASHRAE, 1991, 841991 ANSI ASHRAE
[3]  
*ANSI ASME, 1985, 191 ANSI ASME PTC
[4]  
*ANSI ASME, 1991, 30 ANSI ASME PTC
[5]  
*ASHRAE, 1995, HVAC APPL HDB
[6]  
*ASHRAE, 1996, HVAC SYST EQ HDB
[7]  
CHANG WR, 1994, ASHRAE T, V100, P826
[8]  
DHITAL P, 1995, ASHRAE T, V101, P978
[9]  
Hill J.M., 1994, ASHRAE T RES 1, V100, P91
[10]  
HILL JM, 1993, ASHRAE TRAN, V99, P1315