Potentiometric response and mechanism of anionic recognition of heterocalixarene-based ion selective electrodes

被引:34
作者
Shishkanova, T. V.
Sykora, D.
Sessler, J. L.
Kral, V.
机构
[1] Inst Chem Technol, Dept Analyt Chem, CZ-16628 Prague 6, Czech Republic
[2] Univ Texas, Dept Chem & Biochem, Inst Mol & Cellular Biol, Austin, TX 78712 USA
关键词
potentiometry; ion-selective electrodes; hydroxybenzoate; heterocalixarene; anion recognition; POLYMERIC MEMBRANE ELECTRODES; CYTOSINE-PENDANT TRIAMINE; LIQUID-MEMBRANE; MONOHYDROGEN PHOSPHATE; ACETYLSALICYLIC-ACID; SALICYLATE RESPONSE; IONOPHORES; DERIVATIVES; PORPHYRIN; CARRIER;
D O I
10.1016/j.aca.2007.01.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ion selective electrode (ISE)-based potentiometric approach is shown to be an effective means of characterizing the anion recognition sites in the molecular receptor calix[2]pyridino[2]pyrrole (CPP). In particular, potentiometric pH-measurements involving the use of experimental PVC-membranes based on CPP revealed the existence of both mono- and diprotonated forms of the receptor under readily accessible conditions. Based on these analyses, apparent surface protonation constants for this heterocalixarene were found to lie between 8.5-8.9 (pK(BI)) and 3.3-3.8 (pK(B2))- CPP was found to interact with targeted anionic analytes based on both coulombic and hydrogen bond interactions, as inferred from varying the kinds of ionic sites present within the membrane phase. Potentiometric selectivity studies revealed that CPP preferred "Y-shaped" anions (e.g. acetate, lactate, benzoate) over spherical anions (e.g. fluoride and chloride), fluoride over chloride within the set of spherical anions, and the ortho-isomer over the corresponding meta- and para-isomers in the case of hydroxybenzoate (salicylate and congeners). In the context of this study, the advantages of potentiometric determinations of acetylsalicylic acid using optimized PVC-membranes based on CPP relative to more conventional PVC-membrane ISEs based on traditional anion exchanger were also demonstrated. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 51 条
[1]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[2]   An ion-selective electrode for acetate based an a urea-functionalized porphyrin as a hydrogen-bonding ionophore [J].
Amemiya, S ;
Bühlmann, P ;
Umezawa, Y ;
Jagessar, RC ;
Burns, DH .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1049-1054
[3]   Synthesis of novel uranyl salophene derivatives and evaluation as sensing molecules in chemically modified field effect transistors (CHEMFETs) [J].
Antonisse, MMG ;
Snellink-Ruël, BHM ;
Ion, AC ;
Engbersen, JFJ ;
Reinhoudt, DN .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1999, (06) :1211-1218
[4]   Metalloporphyrin-based polymer membrane electrode with high selectivity for 2-hydroxybenzhydroxamate [J].
Badr, IHA ;
Meyerhoff, ME ;
Hassan, SSM .
ANALYTICA CHIMICA ACTA, 1996, 321 (01) :11-19
[5]   Synthesis of functional meso-aryl porphomonomethenes and porphodimethenes:: Application to the preparation of a chiral calix[4]phyrin dimer [J].
Bernátková, M ;
Andrioletti, B ;
Král, V ;
Rose, E ;
Vaissermann, J .
JOURNAL OF ORGANIC CHEMISTRY, 2004, 69 (23) :8140-8143
[6]   Monomer and polymer quinoxaline derivatives for cationic recognition [J].
Breznová, H ;
Volf, R ;
Král, V ;
Sessler, JL ;
Try, AC ;
Shishkanova, TV .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (08) :1193-1198
[7]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[8]   SALICYLATE-SELECTIVE MEMBRANE-ELECTRODE BASED ON TIN(IV) TETRAPHENYLPORPHYRIN [J].
CHANIOTAKIS, NA ;
PARK, SB ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1989, 61 (06) :566-570
[9]   A SALICYLATE ION-SELECTIVE MEMBRANE-ELECTRODE BASED ON ALIQUAT-336S AND THE ASSAY OF ACETYLSALICYLIC-ACID [J].
CHOI, KK ;
FUNG, KW .
ANALYTICA CHIMICA ACTA, 1982, 138 (JUN) :385-390
[10]   Polymeric membrane electrodes for monohydrogen phosphate and sulfate [J].
Fibbioli, M ;
Berger, M ;
Schmidtchen, FP ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :156-160