Observer accuracy and reproducibility of visual estimation of blood loss in obstetrics: how accurate and consistent are health-care professionals?

被引:80
作者
Yoong, W. [1 ]
Karavolos, S. [1 ]
Damodaram, M. [1 ]
Madgwick, K. [2 ]
Milestone, N. [1 ]
Al-Habib, A. [1 ]
Fakokunde, A. [1 ]
Okolo, S. [1 ]
机构
[1] N Middlesex Univ Hosp, Dept Obstet & Gynaecol, London N18 1QX, England
[2] N Middlesex Univ Hosp, Blood Transfus Serv, London N18 1QX, England
关键词
Visual estimation; Blood loss; Test-retest reliability; LABORATORY DETERMINATION; 3RD STAGE; HEMORRHAGE; DELIVERY;
D O I
10.1007/s00404-009-1099-8
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
To evaluate the observer accuracy and intra-observer test-retest reliability of visual estimation of blood loss by midwives and obstetricians. This was a prospective, single-blinded observational study conducted at a London teaching hospital. The accuracy of visually estimating five maternity pads that had been soaked with 25, 50, 100, 150 and 200 ml of blood was assessed. The reproducibility in estimating the same volume (two sets of pads soaked with 50, 100, 150 and 200 ml of blood randomly placed at separate stations) was evaluated by asking participants to visually estimate these volumes. Although there is a tendency to overestimate, the mean percentage difference (estimated-actual volumes) was not significantly different among consultants, trainees and midwives. Visual estimations were especially inaccurate with smaller volumes, which could be overestimated by up to 540%. Test-retest reliability was poor for the larger volumes but statistically acceptable for the smaller volumes, although the difference between the two estimates of the same volume could be as much as 300%. Visual estimations were inaccurate by health-care professionals who have a tendency to overestimate. Experience did not appear to have a confounding effect on accuracy. Further training in visual assessment skills is necessary in order to improve the clinicians' estimation.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 17 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Improving the accuracy of estimated blood loss at obstetric haemorrhage using clinical reconstructions [J].
Bose, P. ;
Regan, F. ;
Paterson-Brown, S. .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2006, 113 (08) :919-924
[3]  
*BRIT STAND I PREC, 1979, GUID DET REPR STAND
[4]  
Buckland Sara S, 2007, Women Birth, V20, P85, DOI 10.1016/j.wombi.2007.01.001
[5]  
Cameron M J., 2006, A Textbook of postpartum hemorrhage, V1st edn, P17
[6]   Estimating blood loss: Can teaching significantly improve visual estimation? [J].
Dildy, GA ;
Paine, AR ;
George, NC ;
Velasco, C .
OBSTETRICS AND GYNECOLOGY, 2004, 104 (03) :601-606
[7]   DISCREPANCY BETWEEN LABORATORY DETERMINATION AND VISUAL ESTIMATION OF BLOOD-LOSS DURING NORMAL DELIVERY [J].
DUTHIE, SJ ;
VEN, D ;
YUNG, GLK ;
GUANG, DZ ;
CHAN, SYW ;
MA, HK .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1991, 38 (02) :119-124
[8]  
Kodkany BS., 2006, TXB POSTPARTUM HEMOR, P35
[9]  
Lewis G., 2007, 7 REPORT CONFIDENTIA
[10]  
Lewis G., 2004, Confidential Enquiry into Maternal and Child Health Improving care for mothers, babies and children Why Mothers Die 2000-2002