Analysis of a femoral hip prosthesis designed to reduce stress shielding

被引:159
作者
Joshi, MG
Advani, SG
Miller, F
Santare, MH [1 ]
机构
[1] Univ Delaware, Dept Engn Mech, Newark, DE 19716 USA
[2] Alfred I Dupont Inst, Dept Pediat Orthoped, Wilmington, DE 19899 USA
关键词
orthopedics; prosthesis; stress; design;
D O I
10.1016/S0021-9290(00)00110-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The natural stress distribution in the femur is significantly altered after total hip arthroplasty (THA). When an implant is introduced, it will carry a portion of the load, causing a reduction of stress in some regions of the remaining bone. This phenomenon is commonly known as stress shielding. In response to the changed mechanical environment the shielded bone will remodel according to Wolff's law, resulting in a lass of bone mass through the biological process called resorption. Resorption can, in turn, cause or contribute to loosening of the prosthesis. The problem is particularly common among younger THA recipients. This study explores the hypothesis that through redesign, a total hip prosthesis can be developed to substantially reduce stress shielding. First, we describe the development of a new femoral hip prosthesis designed to alleviate this problem through a new geometry and system of proximal fixation. A numerical comparison with a conventional intramedullary prosthesis as well as another proximally fixed prosthesis, recently developed by Munting and Verhelpen (1995. Journal of Biomechanics 28(8), 949-961) is presented. The results show that the new design produces a more physiological stress state in the proximal femur. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1655 / 1662
页数:8
相关论文
共 24 条
[1]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]   Charnley total hip arthroplasty in patients less than fifty years old - A twenty to twenty-five-year follow-up note [J].
Callaghan, JJ ;
Forest, EE ;
Olejniczak, JP ;
Goetz, DD ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :704-714
[3]   ANCHORAGE OF THE FEMORAL HEAD PROSTHESIS TO THE SHAFT OF THE FEMUR [J].
CHARNLEY, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1960, 42 (01) :28-30
[4]   ROLE OF LOADS AND PROSTHESIS MATERIAL PROPERTIES ON THE MECHANICS OF THE PROXIMAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY [J].
CHEAL, EJ ;
SPECTOR, M ;
HAYES, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (03) :405-422
[5]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[6]  
ENGH CA, 1997, CLIN ORTHOP RELAT R, P340
[7]   THE SYNOVIAL-LIKE MEMBRANE AT THE BONE-CEMENT INTERFACE IN LOOSE TOTAL HIP REPLACEMENTS AND ITS PROPOSED ROLE IN BONE LYSIS [J].
GOLDRING, SR ;
SCHILLER, AL ;
ROELKE, M ;
ROURKE, CM ;
ONEILL, DA ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (05) :575-584
[8]  
HUISKES R, 1990, CLIN ORTHOP RELAT R, P27
[9]   A SURVEY OF FINITE-ELEMENT ANALYSIS IN ORTHOPEDIC BIOMECHANICS - THE 1ST DECADE [J].
HUISKES, R ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1983, 16 (06) :385-&
[10]  
HUISKES R, 1995, BRIS MYER Z, P159