Square wave voltammetry versus electrochemical impedance spectroscopy as a rapid detection technique at electrochemical immunosensors

被引:86
作者
Liu, Xiaoqiang [1 ]
Duckworth, Paul A. [2 ]
Wong, Danny K. Y. [1 ]
机构
[1] Macquarie Univ, Dept Chem & Biomol Sci, Sydney, NSW 2109, Australia
[2] eDAQ Pty Ltd, Denistone E, NSW 2112, Australia
关键词
Square wave voltammetry; Electrochemical impedance spectroscopy; Label-free immunosensors; Thiolated Protein G-scaffold; Estradiol detection; PROSTATE-SPECIFIC ANTIGEN; LABEL-FREE IMMUNOSENSOR; THIOLATED PROTEIN-G; CARBON NANOTUBE; ANTIBODY; ARRAY; GOLD; NANOPARTICLES; PICOGRAM; BINDING;
D O I
10.1016/j.bios.2009.10.047
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Square wave voltammetry (SWV) was compared to electrochemical impedance spectroscopy (EIS) in developing a label-free electrochemical immunosensor for the hormone estradiol. The immunosensor consists of a Au electrode anchored with a Au nanoparticle vertical bar thiolated Protein G-scaffold to facilitate immobilisation of an enhanced quantity of an almost uprightly aligned anti-estradiol capture antibody. Competitive immunoassays between an estradiol-bovine saline albumin complex and free estradiol in a sample were then promoted at the immunosensor. Next, SWV and EIS of [Fe(CN)(6)](3-/4-) were sequentially-conducted at the immunosensor. SWV yielded familiar peak-shaped voltammograms with the peak currents readily employable in establishing calibration. A dynamic range up to similar to 1200 pg mL(-1) and a detection limit of 18 pg mL(-1) estradiol were achieved. In EIS, an electron transfer resistance estimated from the Nyquist plots was used in the calibration experiments. A comparable dynamic range up to similar to 1000 pg mL(-1) and a detection limit of 26 pg mL(-1) estradiol were obtained. However, a significantly 10 times longer analysis time and substantial effort were required to complete the EIS determinations relative to SWV. Moreover, a large amount of EIS data involving phase angle was collected but ignored because they would not contribute any useful information to quantitative determination. Overall, SWV was determined to be a more rapid, efficient, effective and low cost detection technique than EIS at label-free electrochemical immunosensors. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1467 / 1473
页数:7
相关论文
共 29 条
[1]   Signal generation at an electrochemical immunosensor via the direct oxidation of an electroactive label [J].
Akram, M ;
Stuart, MC ;
Wong, DKY .
ELECTROANALYSIS, 2006, 18 (03) :237-246
[2]   Microfluidic immunosensor systems [J].
Bange, A ;
Halsall, HB ;
Heineman, WR .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2488-2503
[3]   Labeless immunosensor assay for prostate specific antigen with picogram per milliliter limits of detection based upon an ac impedance protocol [J].
Barton, Andrew C. ;
Davis, Frank ;
Higson, Seamus P. J. .
ANALYTICAL CHEMISTRY, 2008, 80 (16) :6198-6205
[4]   Challenges of Electrochemical Impedance Spectroscopy in Protein Biosensing [J].
Bogomolova, A. ;
Komarova, E. ;
Reber, K. ;
Gerasimov, T. ;
Yavuz, O. ;
Bhatt, S. ;
Aldissi, M. .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :3944-3949
[5]   Impedance immunosensor based on receptor protein adsorbed directly on porous gold film [J].
Chen, ZP ;
Jiang, JH ;
Shen, GL ;
Yu, RQ .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :190-195
[6]   Comparative study of thiolated Protein G scaffolds and signal antibody conjugates in the development of electrochemical immunosensors [J].
Fowler, Jeremy A. ;
Stuart, Margaret C. ;
Wong, Danny K. Y. .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (05) :633-639
[7]   Self-assembled layer of thiolated protein G as an immunosensor scaffold [J].
Fowler, Jeremy M. ;
Stuart, Margaret C. ;
Wong, Danny K. Y. .
ANALYTICAL CHEMISTRY, 2007, 79 (01) :350-354
[8]  
Fowler JM, 2008, ELECTROCHEMICAL SENSORS, BIOSENSORS AND THEIR BIOMEDICAL APPLICATIONS, P115, DOI 10.1016/B978-012373738-0.50007-6
[9]   SIMULTANEOUS IMMUNOASSAY USING ELECTROCHEMICAL DETECTION OF METAL-ION LABELS [J].
HAYES, FJ ;
HALSALL, HB ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1860-1865
[10]   Development of a label-free electrochemical immunosensor based on carbon nanotube for rapid determination of clenbuterol [J].
He, Pingli ;
Wang, Zongyi ;
Zhang, Liying ;
Yang, Wenjun .
FOOD CHEMISTRY, 2009, 112 (03) :707-714