Maximal oxygen uptake during field running does not exceed that measured during treadmill exercise

被引:34
作者
Meyer, T [1 ]
Welter, JP [1 ]
Scharhag, J [1 ]
Kindermann, W [1 ]
机构
[1] Univ Saarland, Inst Sports & Prevent Med, D-66041 Saarbrucken, Germany
关键词
maximal oxygen uptake; spiroergometry; ambulatory measurements; field test;
D O I
10.1007/s00421-002-0718-x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Modern ergometric equipment enables the simulation of laboratory maximal oxygen uptake VO2max) testing in the field. Therefore, it was investigated whether the improved event specificity on the track might lead to higher VO2max measurements in running. Identical protocols were used on the treadmill and on the track (speed was indicated by a computer-driven flashing light system). Ambulatory measurements of gas exchange were carried out throughout both tests, which were executed in randomized order. There were no significant differences (P = 0.71) in VO2max between treadmill [4.65 (0.51) ml.min(-1)] and field tests [4.63 (0.55) ml.min(-1)]. However, the test duration differed significantly (P < 0.001) by approximately 5%: treadmill 691 (39) s; field test 727 (42) s. With the exception of maximum heart rate (HRmax; significantly higher in the field with P = 0.02) all criteria for the degree of effort were similar between the two tests. However, the difference in HRmax at less than 2 beats.min(-1), was practically negligible. Submaximal measurements of oxygen uptake and minute ventilation were significantly higher on the treadmill (P < 0.001 for both parameters). In summary, field tests with incremental running protocols do not result in higher VO2max measurements compared to laboratory treadmill exercise. A better running economy on the track results in higher maximal velocities and longer exercise durations being sustained. The determination of VO2max is not a reasonable application for ambulatory gas exchange measurements because laboratory values are not surpassed.
引用
收藏
页码:387 / 389
页数:3
相关论文
共 8 条
[1]   OPTIMIZING THE EXERCISE PROTOCOL FOR CARDIOPULMONARY ASSESSMENT [J].
BUCHFUHRER, MJ ;
HANSEN, JE ;
ROBINSON, TE ;
SUE, DY ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (05) :1558-1564
[2]  
DANIELS JT, 1985, MED SCI SPORT EXER, V17, P332
[3]  
HOWLEY ET, 1995, MED SCI SPORT EXER, V27, P1292
[4]   Physiological comparisons among three maximal treadmill exercise protocols in trained and untrained individuals [J].
Kang, J ;
Chaloupka, EC ;
Mastrangelo, MA ;
Biren, GB ;
Robertson, RJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 84 (04) :291-295
[5]   INFLUENCE OF TRACK COMPLIANCE ON RUNNING [J].
MCMAHON, TA ;
GREENE, PR .
JOURNAL OF BIOMECHANICS, 1979, 12 (12) :893-904
[6]  
MCMIKEN DF, 1976, MED SCI SPORT EXER, V8, P14
[7]  
Reinisch M, 1991, Sportverletz Sportschaden, V5, P60, DOI 10.1055/s-2007-993563
[8]  
[No title captured]