Comparison of drug delivery from conventional versus "Venturi" nebulizers

被引:40
作者
Devadason, SG
Everard, ML
Linto, JM
Le Souef, PN
机构
[1] Princess Margaret Hosp Children, Dept Resp Med, Subiaco, WA 6008, Australia
[2] Univ Western Australia, Dept Paediat, Nedlands, WA 6009, Australia
关键词
aerosol therapy; drug delivery; inhalation systems; nebulizer output;
D O I
10.1183/09031936.97.10112479
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Attempts to improve drug delivery from conventional jet nebulizers have included the use of storage systems to reduce drug wastage during exhalation. Venturi nebulizers enhance drug delivery during inhalation, reducing treatment times and drug wastage, This study investigated the effect of age on inhaled dose from a conventional jet nebulizer (Acorn(R)) used both with and without a storage chamber (Mizer(R)), compared to two Venturi nebulizers (Ventstream(R) and Pari LC(R)). Filters were attached to the four nebulizer systems, containing salbutamol, and 18 children with cystic fibrosis (3-16 yrs) inhaled through these devices, The quantity of drug collected on the filter was assessed using ultraviolet spectrophotometry, The particle size distribution of the aerosol from each nebulizer system was measured using laser diffraction. Inspiratory filter deposition using the Acorn(R) was lower than the Acorn(R) with Mizer(R), and both Venturi nebulizers. Filter deposition using the Acorn(R) with Mizer(R) was lower than the Pari LC(R). No trend with age, height or weight was noted using any nebulizer, Aerosol particle size using the Ventstream(R) was lower than the other nebulizer systems. Drug output from both Venturi nebulizers was more efficient than from the jet nebulizer, used with and without the storage chamber, during inhalation by children with cystic fibrosis. The inhaled dose did not change with the patient's age or size using both types of nebulizer.
引用
收藏
页码:2479 / 2483
页数:5
相关论文
共 19 条
[1]  
BARRY PW, 1995, DRUG DELIVERY LUNGS, V6, P98
[2]  
BRAIN JD, 1979, AM REV RESPIR DIS, V120, P1325
[3]   THE INFLUENCE OF AGE ON AEROSOL DEPOSITION IN CHILDREN WITH CYSTIC-FIBROSIS [J].
CHUA, HL ;
COLLIS, GG ;
NEWBURY, AM ;
CHAN, K ;
BOWER, GD ;
SLY, PD ;
LESOUEF, PN .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (12) :2185-2191
[4]   DILUTION OF NEBULIZED AEROSOLS BY AIR ENTRAINMENT IN CHILDREN [J].
COLLIS, GG ;
COLE, CH ;
LESOUEF, PN .
LANCET, 1990, 336 (8711) :341-343
[5]   DRUG NEBULIZER DESIGN AND PERFORMANCE - BREATH ENHANCED JET VS CONSTANT OUTPUT JET VS ULTRASONIC [J].
DENNIS, JH .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1995, 8 (03) :277-280
[6]  
Dolovich M., 1989, J AEROSOL MED, V2, P171
[7]   DRUG DELIVERY FROM JET NEBULIZERS [J].
EVERARD, ML ;
CLARK, AR ;
MILNER, AD .
ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (05) :586-591
[8]  
GONDA I, 1990, CRIT REV THER DRUG, V6, P273
[9]  
JOHNSON MA, 1991, CHEST, V99, P1139
[10]   A NEBULIZER SYSTEM FOR HIGHLY REPRODUCIBLE AEROSOL DELIVERY [J].
KNOCH, M ;
WUNDERLICH, E ;
GELDNER, S .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1994, 7 (03) :229-237