High-performance cation-exchange chromatofocusing of proteins

被引:53
作者
Kang, XZ [1 ]
Frey, DD [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Baltimore, MD 21250 USA
基金
美国国家科学基金会;
关键词
chromatofocusing; pH gradients; cation-exchange chromatofocusing; proteins;
D O I
10.1016/S0021-9673(03)00210-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chromatofocusing using high-performance cation-exchange column packings, as opposed to the more commonly used anion-exchange column packings, is investigated with regard to the performance achieved and the range of applications possible. Linear or convex gradients in the range from pH 2.6 to 9 were formed using a variety of commercially available column packings that provide a buffering capacity in different pH ranges, and either polyampholytes or simple mixtures having a small number (three or fewer) of buffering species as the elution buffer. The resolutions achieved using cation-exchange or anion-exchange chromatofocusing were in general comparable, although for certain pairs of proteins better resolution could be achieved using one type of packing as compared to the other, evidently due to the way electrostatic charges are distributed on the protein surface. Several chromatofocusing methods were investigated that take advantage of the acid-base properties of commercially available cation-exchange column packings. These include the use of gradients with a composite shape, the use of very low pH ranges, and the use of elution buffers containing a single buffering species. The advantages of chromatofocusing over ion-exchange chromatography using a salt gradient at constant pH were illustrated by employing the former method and a cation-exchange column packing to separate beta-lactoglobulins A and B, which is a separation reported to be impossible using the latter method and a cation-exchange column packing. Trends in the apparent isoelectric points determined using cation- and anion-exchange chromatofocusing were interpreted using applicable theories. Results of this study indicate that cation-exchange chromatofocusing is a useful technique which is complementary to anion-exchange chromatofocusing and isoelectric focusing for separating proteins at both the analytical and preparative scales. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:117 / 128
页数:12
相关论文
共 34 条
[1]   CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS ON POLY(ASPARTIC ACID) SILICA [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 266 (AUG) :23-37
[2]  
*AM PHARM BIOT, 1999, BIOD 99 PROD CAT, P532
[3]   High-performance chromatofocusing using linear and concave pH gradients formed with simple buffer mixtures I. Effect of buffer composition on the gradient shape [J].
Bates, RC ;
Kang, XZ ;
Frey, DD .
JOURNAL OF CHROMATOGRAPHY A, 2000, 890 (01) :25-36
[4]   Quasi-linear pH gradients for chromatofocusing using simple buffer mixtures: local equilibrium theory and experimental verification [J].
Bates, RC ;
Frey, DD .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :43-54
[5]  
BATES RC, 1999, THESIS U MARYLAND BA
[6]   STERIC MASS-ACTION ION-EXCHANGE - DISPLACEMENT PROFILES AND INDUCED SALT GRADIENTS [J].
BROOKS, CA ;
CRAMER, SM .
AICHE JOURNAL, 1992, 38 (12) :1969-1978
[7]   CHROMATOFOCUSING OF SIALOGLYCOPROTEINS [J].
BURNESS, ATH ;
PARDOE, IU .
JOURNAL OF CHROMATOGRAPHY, 1983, 259 (03) :423-432
[8]  
Cannan RK, 1942, J BIOL CHEM, V142, P803
[9]  
CHIARELLI P, 1988, PROGR COLLOID POLYM, V78, P4
[10]   SINGLE AMINO-ACID CONTRIBUTIONS TO PROTEIN RETENTION IN CATION-EXCHANGE CHROMATOGRAPHY - RESOLUTION OF GENETICALLY ENGINEERED SUBTILISIN VARIANTS [J].
CHICZ, RM ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2059-2066