A review of inlet air-cooling technologies for enhancing the performance of combustion turbines in Saudi Arabia

被引:115
作者
Al-Ibrahim, Abdulrahman M. [1 ]
Varnham, Abdulhadi [1 ]
机构
[1] King Abdulaziz City Sci & Technol, Energy Res Inst, Riyadh 11442, Saudi Arabia
关键词
Combustion turbine; Inlet air cooling; Thermal energy storage; CYCLE GAS-TURBINE; POWER-PLANT; REFRIGERATION CYCLE; ENERGY; SYSTEMS; AUGMENTATION; OPTIMIZATION; IMPROVEMENT;
D O I
10.1016/j.applthermaleng.2010.04.025
中图分类号
O414.1 [热力学];
学科分类号
摘要
Peak demand for electric power in Saudi Arabia occurs during the middle of the day in summer and is almost double the off-peak demand. The demand profile is ill-matched to the performance profile of combustion turbines as their power output decreases with increased inlet-air temperature. Approximately 42% of the Saudi Electric Company's (SEC) annual energy sales are generated by combustion turbines, yet the turbines experience a 24% decrease in system capacity during the summer due to ambient air temperatures up to 50 degrees C. Methods of increasing the energy contribution of existing plant by changing their performance profiles through inlet air cooling could make a substantial contribution to the additional 35 GW in peak demand capacity required by 2023. An extensive review of the various combustion turbine inlet cooling technology (CTIAC) options open to SEC has been made, and their key benefits and drawbacks in relation to the environmental conditions and generational requirements of Saudi Arabia have been identified. (C) 2010 Published by Elsevier Ltd.
引用
收藏
页码:1879 / 1888
页数:10
相关论文
共 69 条
[1]  
Abdalla K.N., 2006, Sudan Eng.Soc.J, V52, P7
[2]   Systematic assessment of combustion turbine inlet air-cooling techniques [J].
Al-Amiri, AM ;
Zamzam, MM .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2005, 127 (01) :159-169
[3]  
Al-Ansary HA, 2007, PROCEEDINGS OF THE ENERGY SUSTAINABILITY CONFERENCE 2007, P231
[4]  
ALBORTMANY JN, 2002, P ASME TURB EXP 2002, P3
[5]   Augmentation of gas turbine performance using air coolers [J].
Alhazmy, MM ;
Najjar, YSH .
APPLIED THERMAL ENGINEERING, 2004, 24 (2-3) :415-429
[6]   Influence of the relative humidity on the air cooling thermal load in gas turbine power plant [J].
Amell, AA ;
Cadavid, FJ .
APPLIED THERMAL ENGINEERING, 2002, 22 (13) :1529-1533
[7]  
AMEN M, 2005, APPL THERM ENG, V25, P241
[8]   The study of capacity enhancement of the Chabahar gas turbine installation using an absorption chiller [J].
Ameri, M ;
Hejazi, SH .
APPLIED THERMAL ENGINEERING, 2004, 24 (01) :59-68
[9]   Comparison of evaporative inlet air cooling systems to enhance the gas turbine generated power [J].
Ameri, Mohammad ;
Shahbazian, H. R. ;
Nabizadeh, M. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (15) :1483-1503
[10]  
Andrepont J. S., 1994, Proceedings of the American Power Conference, P1345