Extensive coagulation monitoring in patients after implantation of the MicroMed Debakey continuous flow axial pump

被引:22
作者
Bonaros, N
Mueller, MR
Salat, A
Schima, H
Roethy, W
Rocher, AA
Wolner, E
Wieselthaler, GM
机构
[1] Univ Innsbruck, Dept Cardiac Surg, A-6020 Innsbruck, Austria
[2] Univ Vienna, Dept Cardiothorac Surg, Vienna, Austria
[3] Univ Vienna, Dept Gen Surg, Vienna, Austria
关键词
D O I
10.1097/01.MAT.0000136515.97686.A2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ventricular assist device (VAD) implantation is associated with impaired primary hemostasis and thromboembolic complications. Recently, a new generation of implantable continuous flow axial pumps was introduced into clinical application. To study the potential thrombogenic properties of this type of pump, we applied extensive platelet monitoring was applied. in our institution, 13 patients received the MicroMed DeBakey VAD as a bridge to transplantation. Routine coagulation tests (platelet count, activated partial thromboplastin time, prothrombin time, antithrombin III activity) and platelet function tests (whole blood aggregometry, thrombelastography, flow cytometry) were performed. No clinically relevant thromboembolic events were detected. No correlation was found between global function tests, platelet aggregation, and thrombelastography. No correlation was detected between platelet activation and hemolysis parameters. Platelet aggregation and coagulation index were significantly suppressed early after operation. A subsequent phase of hyperaggregability, starting around day 6, suggested the initiation of antiaggregation therapy. Platelet activation markers were upregulated in the postoperative period but were returned to preoperative levels after initiation of aspirin. In contrast to routine coagulation monitoring, platelet function tests reflect in detail the coagulation status of blood pump recipients and the efficiency of antiaggregation therapy. Aspirin and dipyridamole therapy in addition to oral anticoagulation using phenprocoumon may contribute to platelet function and clot mechanics restoration and is, therefore, recommended for patients after VAD implantation.
引用
收藏
页码:424 / 431
页数:8
相关论文
共 37 条
[1]   Transitory immunologic response after implantation of the DeBakey VAD continuous-axial-flow pump [J].
Ankersmit, HJ ;
Wieselthaler, G ;
Moser, B ;
Gerlitz, S ;
Roth, G ;
Boltz-Nitulescu, G ;
Wolner, E .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (03) :557-561
[2]  
Ankersmit J, 1999, CIRCULATION, V100, P802
[3]  
Bozzo J, 1995, CARDIOVASC RES, V30, P725, DOI 10.1016/0008-6363(95)00099-2
[4]   A miniature implantable axial flow ventricular assist device [J].
DeBakey, ME .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :637-640
[5]  
DEBAKEY ME, 1998, HEART REPLACEMENT AR, P407
[6]   Platelet morphology in patients with mechanical circulatory support [J].
Dewald, O ;
Fischlein, T ;
Vetter, HO ;
Schmitz, C ;
Godje, O ;
Gohring, P ;
Reichart, R .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 12 (04) :634-641
[7]   Long-term follow-up of thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular function [J].
Farrar, DJ ;
Holman, WR ;
McBride, LR ;
Kormos, RL ;
Icenogle, TB ;
Hendry, PJ ;
Moore, CH ;
Loisance, DY ;
El-Banayosy, A ;
Frazier, H .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2002, 21 (05) :516-521
[8]   REDUCTION OF HEMORRHAGIC COMPLICATIONS DURING MECHANICALLY ASSISTED CIRCULATION WITH THE USE OF A MULTISYSTEM ANTICOAGULATION PROTOCOL [J].
GLAUBER, M ;
SZEFNER, J ;
SENNI, M ;
GAMBA, A ;
MAMPRIN, F ;
FIOCCHI, R ;
SOMASCHINI, M ;
FERRAZZI, P .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1995, 18 (10) :649-655
[9]   Profile and prevalence of aspirin resistance in patients with cardiovascular disease [J].
Gum, PA ;
Kottke-Marchant, K ;
Poggio, EC ;
Gurm, H ;
Welsh, PA ;
Brooks, L ;
Sapp, SK ;
Topol, EJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (03) :230-235
[10]  
HIMMELREICH G, 1995, ASAIO J, V41, pM790, DOI 10.1097/00002480-199507000-00122