Surface modification of thermoplastics - towards the plastic biochip for high throughput screening devices

被引:98
作者
Diaz-Quijada, Gerardo A.
Peytavi, Regis
Nantel, Andre
Roy, Emmanuel
Bergeron, Michel G.
Dumoulin, Michel M.
Veres, Teodor
机构
[1] Natl Res Council Canada, Inst Ind Mat, Boucherville, PQ J4B 6Y4, Canada
[2] Univ Laval, Ctr Rech Infect, Ste Foy, PQ G1K 7P4, Canada
[3] Natl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H4P 2R2, Canada
关键词
D O I
10.1039/b700322f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microarrays have become one of the most convenient tools for high throughput screening, supporting major advances in genomics and proteomics. Other important applications can be found in medical diagnostics, detection of biothreats, drug discovery, etc. Integration of microarrays with microfluidic devices can be highly advantageous in terms of portability, shorter analysis time and lower consumption of expensive biological analytes. Since fabrication of microfluidic devices using traditional materials such as glass is rather expensive, there is great interest in employing polymeric materials as a low cost alternative that is suitable for mass production. A number of commercially available plastic materials were reviewed for this purpose and poly( methylmethacrylate) Zeonor 1060R and Zeonex E48R were identified as promising candidates, for which methods for surface modification and covalent immobilization of DNA oligonucleotides were developed. In addition, we present proof-of-concept plastic-based microarrays with and without integration with microfluidics.
引用
收藏
页码:856 / 862
页数:7
相关论文
共 36 条
[1]  
Ahn C, 2002, MATER RES SOC SYMP P, V729, P131
[2]  
[Anonymous], LANGES HDB CHEM
[3]   OXIDATIVE DEGRADATION OF POLYETHYLENE [J].
BEACHELL, HC ;
NEMPHOS, SP .
JOURNAL OF POLYMER SCIENCE, 1956, 21 (97) :113-124
[4]  
Beamson G., 1992, HIGH RESOLUTION XPS, DOI DOI 10.1002/ADMA.19930051035
[5]   HEXESTROL DIAZIRINE PHOTOAFFINITY-LABELING REAGENT FOR THE ESTROGEN-RECEPTOR [J].
BERGMANN, KE ;
CARLSON, KE ;
KATZENELLENBOGEN, JA .
BIOCONJUGATE CHEMISTRY, 1994, 5 (02) :141-150
[6]  
Bundgaard F., 2004, MICROTOTAL ANAL SYST, V2, P372
[7]   High-sensitivity miniaturized immunoassays for tumor necrosis factor a using microfluidic systems [J].
Cesaro-Tadic, S ;
Dernick, G ;
Juncker, D ;
Buurman, G ;
Kropshofer, H ;
Michel, B ;
Fattinger, C ;
Delamarche, E .
LAB ON A CHIP, 2004, 4 (06) :563-569
[8]   ORIENTED AND COVALENT IMMOBILIZATION OF TARGET MOLECULES TO SOLID SUPPORTS - SYNTHESIS AND APPLICATION OF A LIGHT-ACTIVATABLE AND THIOL-REACTIVE CROSS-LINKING REAGENT [J].
COLLIOUD, A ;
CLEMENCE, JF ;
SANGER, M ;
SIGRIST, H .
BIOCONJUGATE CHEMISTRY, 1993, 4 (06) :528-536
[9]   THE ACTION OF OXYGEN CORONA AND OF OZONE ON POLYETHYLENE [J].
COOPER, GD ;
PROBER, M .
JOURNAL OF POLYMER SCIENCE, 1960, 44 (144) :397-409
[10]   Surface studies of low molecular weight photolysis products from UV-ozone oxidised polystyrene [J].
Davidson, MR ;
Mitchell, SA ;
Bradley, RH .
SURFACE SCIENCE, 2005, 581 (2-3) :169-177