Injectable electronic identification, monitoring, and stimulation systems

被引:46
作者
Troyk, PR [1 ]
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[2] IIT, Pritzker Inst Med Engn, Chicago, IL 60616 USA
关键词
microstimulator; RFID; transcutaneous coupling; micromodules;
D O I
10.1146/annurev.bioeng.1.1.177
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Historically, electronic devices such as pacemakers and neuromuscular stimulators have been surgically implanted into animals and humans. A new class of implants made possible by advances in monolithic electronic design and implant packaging is small enough to be implanted by percutaneous injection through large-gauge hypodermic needles and does not require surgical implantation. Among these, commercially available implants, known as radio frequency identification (RFID) tags, are used for livestock, pet, laboratory animal, and endangered-species identification. The RFID tag is a subminiature glass capsule containing a solenoidal coil and an integrated circuit. Acting as the implanted half of a transcutaneous magnetic link, the RFID tag is powered by and communicates with an extracorporeal magnetic reader. The tag transmits a unique identification code that serves the function of identifying the animal. Millions of RFID tags have been sold since the: early 1980s. Based on the success of the RFID tags, research laboratories have developed injectable medical implants, known as micromodules. One type of micromodule, the microstimulator, is designed for use in functional-neuromuscular stimulation. Each microstimulator is uniquely addressable and could comprise one channel of a multichannel functional-neuromuscular stimulation system. Using bidirectional telemetry and commands, from a single extracorporeal transmitter, as many as 256 microstimulators could form the hardware basis for a complex functional-neuromuscular stimulation feedback-control system. Uses include stimulation of paralyzed muscle, therapeutic functional-neuromuscular stimulation, and neuromodulatory functions such as laryngeal stimulation and sleep apnea.
引用
收藏
页码:177 / 209
页数:33
相关论文
共 62 条
[1]  
BALL DJ, 1991, LAB ANIM SCI, V41, P185
[2]  
Beigel M., 1982, U.S. Patent, Patent No. [4,333,072, 4333072]
[3]   Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles [J].
Cameron, T ;
Liinamaa, TL ;
Loeb, GE ;
Richmond, FJR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (08) :1024-1035
[4]   Effects of regional stimulation using a miniature stimulator implanted in feline posterior biceps femoris [J].
Cameron, T ;
Richmond, FJR ;
Loeb, GE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (08) :1036-1043
[5]   Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs [J].
Cameron, T ;
Loeb, GE ;
Peck, RA ;
Schulman, JH ;
Strojnik, P ;
Troyk, PR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (09) :781-790
[6]  
Campbell J M, 1992, Assist Technol, V4, P4
[7]  
Carroll G. T., 1989, U.S. Patent, Patent No. [4,857,893, 4857893]
[8]  
CARROLL GT, 1988, Patent No. 4724427
[9]   CHOICE OF PULSE DURATION FOR CHRONIC ELECTRICAL-STIMULATION VIA SURFACE, NERVE, AND INTRAMUSCULAR ELECTRODES [J].
CRAGO, PE ;
PECKHAM, PH ;
MORTIMER, JT ;
VANDERME.JP .
ANNALS OF BIOMEDICAL ENGINEERING, 1974, 2 (03) :252-264
[10]  
DeMichele G. A., 1992, U.S. Patent, Patent No. [5,084,699, 5084699]