Determination of diphenhydramine by capillary electrophoresis with tris(2,2′-bipyridyl)ruthenium(II) electrochemiluminescence detection

被引:72
作者
Liu, JF [1 ]
Cao, WD [1 ]
Yang, XR [1 ]
Wang, EK [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary electrophoresis; electrochemiluminescence detection; diphenhydramine; rabbit plasma; rabbit urine;
D O I
10.1016/S0039-9140(02)00535-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence detection in a capillary electrophoresis separation system was used for the determination of diphenhydramine. In this study, platinum disk electrode (300 mum in diameter) was used as a working electrode and the influence of applied potential and buffer conditions were investigated. Under optimal conditions: 1.2 V applied potential, pH 8.50, 15 kV separation voltage and 10 mmol l(-1) running buffer, the calibration curve of diphenhydramine was linear over the range of 4 x 10(-8) to 1 x 10(-5) Mol l(-1). This technique gave satisfactory precision, and relative standard deviations of migration times and chemiluminescence peak intensities were less than 1 and 6%, respectively. The technique was applied to animal studies for determination of diphenhydramine extracted from rabbit plasma and urine samples, and the extraction efficiency were between 92 and 98.5%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:453 / 459
页数:7
相关论文
共 38 条
[1]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[2]   Optimization and validation of a method for the determination of caffeine, 8-chlorotheophylline and diphenhydramine by isocratic high-performance liquid chromatography -: Stress test for stability evaluation [J].
Barbas, C ;
García, A ;
Saavedra, L ;
Castro, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :97-103
[3]   Determination of codeine, 6-methoxycodeine and thebaine using capillary electrophoresis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW ;
Purcell, SD .
ANALYTICAL COMMUNICATIONS, 1998, 35 (10) :321-324
[4]  
Beale SC, 1998, ANAL CHEM, V70, p279R
[5]   Chemiluminescent detection of amines and amino acids using in situ generated Ru(bpy)33+ following separation by capillary electrophoresis [J].
Bobbitt, DR ;
Jackson, WA ;
Hendrickson, HP .
TALANTA, 1998, 46 (04) :565-572
[6]   EFFECT OF PH ON THE REACTION OF TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III) WITH AMINO-ACIDS - IMPLICATIONS FOR THEIR DETECTION [J].
BRUNE, SN ;
BOBBITT, DR .
TALANTA, 1991, 38 (04) :419-424
[7]   Chemiluminescence detection in capillary electrophoresis [J].
Campana, AMG ;
Baeyens, WRG ;
Zhao, YN .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :A83-A88
[8]  
CLAIRE RL, 1996, ANAL CHEM, V68, pR569
[9]  
Dickson JA, 1997, HRC-J HIGH RES CHROM, V20, P643
[10]   Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications [J].
Erdem, A ;
Ozsoz, M ;
Kirilmaz, L ;
Kilinc, E ;
Dalbasti, T .
ELECTROANALYSIS, 1997, 9 (12) :932-935