An evaluation of Ektaspeed Plus film versus Ultraspeed film for endodontic working length determination

被引:9
作者
Brown, R
Hadley, JN
Chambers, DW
机构
[1] Univ Pacific, Sch Dent, Dept Endodont, San Francisco, CA 94115 USA
[2] Univ Pacific, Sch Dent, Dept Radiol, San Francisco, CA 94115 USA
[3] Univ Pacific, Sch Dent, Emergency Serv, San Francisco, CA 94115 USA
关键词
D O I
10.1016/S0099-2399(98)80216-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Thirteen teeth in human cadaver sections were accessed and #15 K-files were placed at various lengths in one root canal of each tooth, Using a positioner to ensure duplicate views, radiographs were taken with both Ultraspeed and Ektaspeed Plus X-ray film, Each of the 26 radiographs was coded and then placed in random order, Six endodontic specialists measured the distance from the file tip to the radiographic apex on each film, The results were analyzed by analysis of variance and Cronbach's generalizability theory, It was found that 94% of the variance in measurements was due to differences among the viewers, whereas 5% was due to a combination of viewers and tooth, Only 1% was due to differences between the two types of film, It was concluded that Ektaspeed Plus film may be used for working length radiographs because it requires only similar to 50% of the radiation needed for Ultraspeed film.
引用
收藏
页码:54 / 56
页数:3
相关论文
共 12 条
[1]  
*AAE, 1994, GLOSS CONT TERM END, P25
[2]  
[Anonymous], 1972, The dependability of behaviourial measurements: Theory of generalzsability for scores and profiles
[3]   CLINICAL-EVALUATION OF EKTASPEED X-RAY-FILM FOR USE IN ENDODONTICS [J].
DONNELLY, JC ;
HARTWELL, GR ;
JOHNSON, WB .
JOURNAL OF ENDODONTICS, 1985, 11 (02) :90-94
[4]   AN EVALUATION OF KODAK EKTASPEED PERIAPICAL FILM FOR USE IN ENDODONTICS [J].
GIRSCH, WJ ;
MATTESON, SR ;
MCKEE, MN .
JOURNAL OF ENDODONTICS, 1983, 9 (07) :282-288
[5]   SURVEY OF RADIOLOGIC PRACTICES AMONG DENTAL PRACTITIONERS [J].
GOREN, AD ;
SCIUBBA, JJ ;
FRIEDMAN, R ;
MALAMUD, H .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 67 (04) :464-468
[6]  
INGLE JI, 1985, ENDODONTICS, P189
[7]   2 DENTAL-X-RAY FILMS COMPARED FOR RATER PREFERENCE USING ENDODONTIC VIEWS [J].
KLEIER, DJ ;
BENNER, SJ ;
AVERBACH, RE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1985, 59 (02) :201-205
[8]   COMPLIANCE OF MICHIGAN DENTISTS WITH RADIOGRAPHIC SAFETY RECOMMENDATIONS [J].
NAKFOOR, CA ;
BROOKS, SL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 73 (04) :510-513
[9]   THE USE OF E-SPEED FILM FOR ROOT-CANAL LENGTH DETERMINATION [J].
POWELLCULLINGFORD, AW ;
FORD, TRP .
INTERNATIONAL ENDODONTIC JOURNAL, 1993, 26 (05) :268-272
[10]   SENSITOMETRIC COMPARISON OF KODAK EKTASPEED PLUS, EKTASPEED, AND ULTRA-SPEED DENTAL FILMS [J].
THUNTHY, KH ;
WEINBERG, R .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 79 (01) :114-116