Midterm endothelial function and remodeling of radial artery grafts anastomosed to the aorta

被引:24
作者
Gaudino, M
Glieca, F
Trani, C
Lupi, A
Mazzari, MA
Schiavoni, G
Possati, G
机构
[1] Catholic Univ, Dept Cardiac Surg, Rome, Italy
[2] Catholic Univ, Dept Cardiol, Rome, Italy
关键词
D O I
10.1067/mtc.2000.108015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The purpose of this study was to elucidate the midterm endothelium-dependent vasodilatory capacity of radial artery grafts anastomosed to the aorta, as well as their morphometric evolution with the time. Methods: Five years after surgery we evaluated the response of aorta-anastomosed radial artery grafts to the endovascular infusion of acetylcholine in 11 of the first 61 patients operated on at our institution, and we compared it to the response with that of internal thoracic artery grafts. Moreover, the first 20 patients who had a perfect radial artery graft on angiography at 1 year were restudied at 5 years and subjected to a comparative analysis of the diameters of the radial artery graft and the grafted coronary arteries. Results: At midterm angiography, dilation of the 2 types of grafts was similar in response to acetylcholine administration (radial artery, from 2.61 +/- 0.39 to 2.90 +/- 0.34 mm; internal thoracic artery, from 2.68 +/- 0.21 to 2.93 +/- 0.27 mm; P =.01 for both). The diameters of aorta-anastomosed radial artery grafts and grafted coronary arteries increased between both 1 and 5 years according to angiographic studies (radial artery grafts, from 2.08 +/- 0.45 to 2.54 +/- 0.53 mm; grafted coronary arteries, from 1.92 +/- 0.47 to 2.18 +/- 0.41 mm; P <.001 for both), but the increase was greater for the radial artery grafts (P <.001). Conclusions: Aorta-anastomosed radial artery grafts maintain an appreciable capacity for endothelium-dependent vasodilatation 5 years after implantation and undergo a progressive increase in luminal diameter with time. These observations contradict the presumed tendency for progressive fibrous intimal hyperplasia to develop in radial artery grafts.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 17 条
  • [1] REVIVAL OF THE RADIAL ARTERY FOR CORONARY-ARTERY BYPASS-GRAFTING
    ACAR, C
    JEBARA, VA
    PORTOGHESE, M
    BEYSSEN, B
    PAGNY, JY
    GRARE, P
    CHACHQUES, JC
    FABIANI, JN
    DELOCHE, A
    GUERMONPREZ, JL
    CARPENTIER, AF
    [J]. ANNALS OF THORACIC SURGERY, 1992, 54 (04) : 652 - 660
  • [2] Barner H B, 1996, Semin Thorac Cardiovasc Surg, V8, P3
  • [3] Routine use of unilateral and bilateral radial arteries for coronary artery bypass graft surgery
    Brodman, RF
    Frame, R
    Camacho, M
    Hu, E
    Chen, A
    Hollinger, I
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (04) : 959 - 963
  • [4] CALAFIORE AM, 1995, J CARDIAC SURG, V10, P140
  • [5] CHARDIGNY C, 1993, CIRCULATION, V88, P115
  • [6] CHEN AH, 1996, J THORAC CARDIOVASC, V111, P208
  • [7] FLOW ACTIVATES AN ENDOTHELIAL POTASSIUM CHANNEL TO RELEASE AN ENDOGENOUS NITROVASODILATOR
    COOKE, JP
    ROSSITCH, E
    ANDON, NA
    LOSCALZO, J
    DZAU, VJ
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1991, 88 (05) : 1663 - 1671
  • [8] daCosta FDA, 1996, ANN THORAC SURG, V62, P475
  • [9] Remodeling of the radial artery in response to a chronic increase in shear stress
    Girerd, X
    London, G
    Boutouyrie, P
    Mourad, JJ
    Safar, M
    Laurent, S
    [J]. HYPERTENSION, 1996, 27 (03) : 799 - 803
  • [10] Radial artery has higher receptor-mediated contractility but similar endothelial function compared with mammary artery
    He, GW
    Yang, CQ
    [J]. ANNALS OF THORACIC SURGERY, 1997, 63 (05) : 1346 - 1352