Removal of interference signals due to water from in vivo near-infrared (NIR) spectra of mood glucose by region orthogonal signal correction (ROSC)

被引:19
作者
Du, YP [1 ]
Liang, YZ
Kasemsumran, S
Maruo, K
Ozaki, Y
机构
[1] Kwansei Gakuin Univ, Sch Sci & Technol, Dept Chem, Sanda 6691337, Japan
[2] Kwansei Gakuin Univ, Sch Sci & Technol, Res Ctr Near Infrared Spect, Sanda 6691337, Japan
[3] Cent S Univ, Coll Chem & Chem Engn, Changsha 410083, Peoples R China
[4] Matsushita Elect Works Ltd, NBT Project, Kadoma, Osaka 5718686, Japan
[5] Shandong Univ Technol, Coll Chem Engn, Zibo 255000, Peoples R China
关键词
D O I
10.2116/analsci.20.1339
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel chemometric method, region orthogonal signal correction (ROSC), is proposed and applied to pretreat near-infrared (NIR) spectra of blood glucose measured in vivo. Water is the most serious interference component in such kinds of noninvasive measurements, because it shows very high absorbance in the spectra. In the present study, the spectra of blood glucose in the range of 1212 - 1889 nm are used, in which the absorption of water around 1440 nm is very high. ROSC aims at removing the interference signal due to water from the spectra by selecting a set of spectra with a special region of 1404 - 1454 nm that mainly contain information about the variation of the interference component, water, and calculating the orthogonal components to the concentrations of glucose that will be removed. The difference between ROSC and orthogonal signal correction (OSC) is that ROSC uses a special region of spectra for the estimation of scores and loading weights of orthogonal components to pretreat the spectra in other regions, while OSC only uses one fixed region of spectra to calculate loadings, scores and weights of OSC components and removes the OSC components in the same region. A clear advantage of ROSC is that it is more interpretable than OSC, because one can select a spectral region to remove the variation of a special component such as water. Another chemometric method, moving window partial least squares (MWPLSR), is also used to select informative regions of glucose from the NIR spectra of blood glucose measured in vivo, leading to improved PLS models. Results of the application of ROSC demonstrate that ROSC-pretreated spectra including the whole spectral region of 1212 - 1889 nm or an informative region of 1600 - 1730 run selected by MWPLSR provide very good performance of the PLS models. Especially, the later region yields a model with RMSECV of 15.8911 mg/dL for four PLS components. ROSC is a potential chemometric technique in the pretreatment of various spectra.
引用
收藏
页码:1339 / 1345
页数:7
相关论文
共 20 条
  • [1] DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA
    ARNOLD, MA
    SMALL, GW
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (14) : 1457 - 1464
  • [2] Burmeister JJ, 1999, CLIN CHEM, V45, P1621
  • [3] Spectral regions selection to improve prediction ability of PLS models by changeable size moving window partial least squares and searching combination moving window partial least squares
    Du, YP
    Liang, YZ
    Jiang, JH
    Berry, RJ
    Ozaki, Y
    [J]. ANALYTICA CHIMICA ACTA, 2004, 501 (02) : 183 - 191
  • [4] On orthogonal signal correction
    Fearn, T
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) : 47 - 52
  • [5] Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determination
    Fischbacher, C
    Jagemann, KU
    Danzer, K
    Muller, UA
    Papenkordt, L
    Schuler, J
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (01): : 78 - 82
  • [6] Heise HM, 1998, JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, P349
  • [7] NONINVASIVE BLOOD-GLUCOSE SENSORS BASED ON NEAR-INFRARED SPECTROSCOPY
    HEISE, HM
    MARBACH, R
    KOSCHINSKY, T
    GRIES, FA
    [J]. ARTIFICIAL ORGANS, 1994, 18 (06) : 439 - 447
  • [8] APPLICATION OF NEAR-INFRARED SPECTROSCOPY FOR NONINVASIVE DETERMINATION OF BLOOD-TISSUE GLUCOSE USING NEURAL NETWORKS
    JAGEMANN, KU
    FISCHBACHER, C
    MULLER, UA
    MERTES, B
    [J]. ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 1995, 191 : 179 - 190
  • [9] Wavelength interval selection in multicomponent spectral analysis by moving window partial least-squares regression with applications to mid-infrared and hear-infrared spectroscopic data
    Jiang, JH
    Berry, RJ
    Siesler, HW
    Ozaki, Y
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (14) : 3555 - 3565
  • [10] Simultaneous determination of human serum albumin, γ-globulin, and glucose in a phosphate buffer solution by near-infrared spectroscopy with moving window partial least-squares regression
    Kasemsumran, S
    Du, YP
    Murayama, K
    Huehne, M
    Ozaki, Y
    [J]. ANALYST, 2003, 128 (12) : 1471 - 1477