Detectability improvements in capillary zone electrophoresis by combining single capillary isotachophoretic preconcentration and frequency doubled argon ion laser-induced fluorescence detection

被引:17
作者
Enlund, AM
Schmidt, S
Westerlund, D
机构
[1] Uppsala Univ, Ctr Biomed, S-75123 Uppsala, Sweden
[2] Astra Arcus AB, Sodertalje, Sweden
关键词
detectability improvements; isotachophoretic preconcentration; frequency doubled argon ion laser; hydrodynamic backpressure programming; capillary zone electrophoresis;
D O I
10.1002/elps.1150190518
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Due to the small path length and low injection volume the concentration limit of detection is comparatively poor in capillary electrophoresis (CZE) with UV detection. This limitation can be overcome by means of preconcentration methods and/or improved detection techniques. This paper describes a strategy where isotachophoresis (ITP) is used to preconcentrate a new cholinesterase inhibitor (NXX-066) prior to a capillary zone electrophoresis analysis in the same single capillary. A hydrodynamic backpressure is used to prevent the analyte from migrating out of the capillary. Laser-induced fluorescence (LIF) is used to further increase the detectability. The total gain in detectability with ITP-CZE-LIF compared to CZE-UV was at least 5500-fold, and it is possible to determine NXX-066 at the 1 nM level. The ITP-CZE method was further evaluated for two beta-blockers; the mean coefficient of variation of the peak areas was 3.4% and the linearity of the calibration plots was satisfying.
引用
收藏
页码:707 / 711
页数:5
相关论文
共 41 条
[1]   SENSITIVITY ENHANCEMENT FOR CAPILLARY ELECTROPHORESIS [J].
ALBIN, M ;
GROSSMAN, PD ;
MORING, SE .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :A489-A497
[2]  
BENSON LM, 1994, HRC-J HIGH RES CHROM, V17, P671
[3]   ONLINE PRECONCENTRATION OF TRIAZINE HERBICIDES WITH TANDEM OCTADECYL CAPILLARIES-CAPILLARY ZONE ELECTROPHORESIS [J].
CAI, J ;
ELRASSI, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (6-7) :1179-1192
[4]   SIMPLE LASER-INDUCED FLUORESCENCE DETECTOR FOR SULFORHODAMINE-101 IN A CAPILLARY ELECTROPHORESIS SYSTEM - DETECTION LIMITS OF 10 YOCTOMOLES OR 6 MOLECULES [J].
CHEN, DY ;
ADELHELM, K ;
CHENG, XL ;
DOVICHI, NJ .
ANALYST, 1994, 119 (02) :349-352
[5]   Single-molecule detection in capillary electrophoresis: Molecular shot noise as a fundamental limit to chemical analysis [J].
Chen, DY ;
Dovichi, NJ .
ANALYTICAL CHEMISTRY, 1996, 68 (04) :690-696
[6]   SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE [J].
CHENG, YF ;
DOVICHI, NJ .
SCIENCE, 1988, 242 (4878) :562-564
[7]   Z-SHAPED FLOW CELL FOR UV-DETECTION IN CAPILLARY ELECTROPHORESIS [J].
CHERVET, JP ;
VANSOEST, REJ ;
URSEM, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (02) :439-449
[8]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[9]   ON-COLUMN SAMPLE CONCENTRATION USING FIELD AMPLIFICATION IN CZE [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :A489-A496
[10]   Evaluation of extended light path capillaries for use in capillary electrophoresis with laser-induced fluorescence detection [J].
Cole, RO ;
Hiller, DL ;
Chwojdak, CA ;
Sepaniak, MJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 736 (1-2) :239-245