Hemodynamic patterns of pharmacologically induced erection: Evaluation by color Doppler sonography

被引:35
作者
Chiou, RK [1 ]
Pomeroy, BD [1 ]
Chen, WS [1 ]
Anderson, JC [1 ]
Wobig, RK [1 ]
Taylor, RJ [1 ]
机构
[1] UNIV NEBRASKA, MED CTR, DEPT RADIOL, OMAHA, NE 68105 USA
关键词
penis; ultrasonics; impotence; hemodynamics;
D O I
10.1016/S0022-5347(01)64028-X
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Penile erection is achieved through hemodynamic mechanisms that can be assessed best with color flow imaging and Doppler waveform analysis, We performed dynamic studies using computer assisted analysis to assess the hemodynamic patterns of pharmacologically induced erection. Materials and Methods: A total of 73 color Doppler ultrasound studies was performed in 66 patients with erectile dysfunction. Various blood flow parameters, including peak systolic velocity, end diastolic velocity, mean flow rate, resistive index and artery diameter, were observed continuously and recorded frequently for about 30 minutes after intracorporeal injection of papaverine/phentolamine/prostaglandin E1 mixture, A computerized Doppler waveform analysis of 3 curves or greater was performed for each recording to minimize error, A second injection was administered if the first injection failed to induce a rigid erection. Status of the erection was observed and recorded throughout the study. A computerized graph was generated for each corpus. Results: After intracorporeal injection the time to reach normal or peak velocity varied from 1 to 24 minutes. Among 146 corpus units in 73 color Doppler ultrasound studies we observed the following hemodynamic patterns: I-normal maximal peak systolic velocity (35 cm. per second or greater), sustained; Ia-end diastolic velocity 0 or less with complete erection response (19 units); Ib-end diastolic velocity greater than 0 or incomplete erection response (14 units); II-normal maximal peak systolic velocity (35 cm, per second or greater), transient; IIa-end diastolic velocity 0 or less with complete erection response (21 units); IIb-end diastolic velocity greater than 0 or incomplete erection response (12 units); III-borderline maximal peak systolic velocity (30 to 35 cm, per second); IIIa-end diastolic velocity 0 or less with complete erection response (10 units); IIIb-end diastolic velocity greater than 0 or incomplete erection response (8 units); IV-low maximal peak systolic velocity (less than 30 cm. per second); IVa-end diastolic velocity 0 or less with complete erection response (24 units); and IVb-end diastolic velocity greater than 0 or incomplete erection response (38 units). Conclusions: Erection is a complex and dynamic process. A new classification of hemodynamic patterns is presented that aids in assessing and interpreting more thoroughly blood flow parameters to stratify more precisely the hemodynamic patterns of erectile dysfunction.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 14 条
[1]   SEXUAL IMPOTENCE CAUSED BY VASCULAR-DISEASE - DIAGNOSIS WITH DUPLEX SONOGRAPHY [J].
BENSON, CB ;
VICKERS, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) :1149-1153
[2]   A positive pharmacological erection test does not rule out arteriogenic erectile dysfunction [J].
Cormio, L ;
Nisen, H ;
Selvaggi, FP ;
Ruutu, M .
JOURNAL OF UROLOGY, 1996, 156 (05) :1628-1630
[3]   TIMING OF PENILE COLOR-FLOW DUPLEX ULTRASONOGRAPHY USING A TRIPLE-DRUG MIXTURE [J].
GOVIER, FE ;
ASASE, D ;
HEFTY, TR ;
MCCLURE, RD ;
PRITCHETT, TR ;
WEISSMAN, RM .
JOURNAL OF UROLOGY, 1995, 153 (05) :1472-1475
[4]   THE VALUE OF INCREASED END DIASTOLIC VELOCITY DURING PENILE DUPLEX SONOGRAPHY IN RELATION TO PATHOLOGICAL VENOUS LEAKAGE IN ERECTILE DYSFUNCTION [J].
KROPMAN, RF ;
SCHIPPER, J ;
VONOOSTAYEN, JA ;
NIJEHOLT, AABLA ;
MEINHARDT, W .
JOURNAL OF UROLOGY, 1992, 148 (02) :314-317
[5]   Penile vascular assessment using color duplex sonography in men with Peyronie's disease [J].
Levine, LA ;
Coogan, CL .
JOURNAL OF UROLOGY, 1996, 155 (04) :1270-1273
[6]  
LUE TF, 1985, RADIOLOGY, V155, P77
[7]   ASSESSMENT OF PENILE BLOOD-FLOW BY DUPLEX ULTRASONOGRAPHY IN 44 MEN WITH NORMAL ERECTILE POTENCY IN DIFFERENT PHASES OF ERECTION [J].
MEULEMAN, EJH ;
BEMELMANS, BLH ;
VANASTEN, WNJC ;
DOESBURG, WH ;
SKOTNICKI, SH ;
DEBRUYNE, FMJ .
JOURNAL OF UROLOGY, 1992, 147 (01) :51-56
[8]   The effect of intracorporeal injection plus genital and audiovisual sexual stimulation versus second injection on penile color Doppler sonography parameters [J].
Montorsi, F ;
Guazzoni, G ;
Barbieri, L ;
Galli, L ;
Rigatti, P ;
Pizzini, G ;
Miani, A .
JOURNAL OF UROLOGY, 1996, 155 (02) :536-540
[9]   THE USE OF DUPLEX ULTRASOUND IN THE ASSESSMENT OF ARTERIAL SUPPLY TO THE PENIS IN VASCULOGENIC IMPOTENCE [J].
OATES, CP ;
PICKARD, RS ;
POWELL, PH ;
MURTHY, LNS ;
WHITTINGHAM, TAW .
JOURNAL OF UROLOGY, 1995, 153 (02) :354-357
[10]   ROLE OF DUPLEX SONOGRAPHY IN THE EVALUATION OF SEXUAL IMPOTENCE [J].
PAUSHTER, DM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) :1161-1163