Comparative accuracy of three automated techniques in the noninvasive estimation of central blood pressure in men

被引:22
作者
Lehmann, KG
Gelman, JA
Weber, MA
Lafrades, A
机构
[1] Univ Washington, Sch Med, Cardiol Sect, Seattle, WA 98195 USA
[2] Dept Vet Affairs Med Ctr, Long Beach, CA USA
[3] Dept Vet Affairs Med Ctr, Sect Cardiol 111C, Seattle, WA 98108 USA
关键词
D O I
10.1016/S0002-9149(98)00080-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Automated devices have regularly replaced manual sphygmomanometry for the determination of blood pressure not only in homes and clinics, but also in emergency and critical care settings. Few studies exist that correctly assess the accuracy of these devices, and even fewer that specifically compare commercially available units that rely on different physiologic events for measurement. Six hundred pressure measurements were obtained from 120 subjects using 1 of 3 randomly selected blood pressure monitors. In addition, central arterial pressure measurements were obtained simultaneously and directly from the ascending aorta of each subject. Overall, these devices tended to overestimate diastolic (+2.5 mm Hg, p <0.0001) and mean (+3.8 mm Hg, p < 0.0001) pressures, but not systolic (+0.7 mm Hg, p = NS) pressure. Compared with the other 2 devices, device I, relying on oscillometric detection, demonstrated a significantly smaller mean absolute error for diastolic pressure (4.9 +/- 3.0 vs 7.0 +/- 4.8 and 6.2 +/- 5.3 mm Hg, p <0.0001) and mean pressure (4.0 +/- 3.2 vs 7.8 +/- 5.9 and 8.6 +/- 7.5 mm Hg, p <0.0001), and a trend toward smaller error with systolic pressure (6.8 +/- 6.5 vs 7.3 +/- 6.8 and 8.0 +/- 5.6 mm Hg, p = 0.19). Clinically significant (+/-10 mm Hg) errors were common with each device (24.8% overall), but serious (+/-20 mm Hg) errors were unusual (3.2%) and did not occur at all with device I during diastolic and mean pressure measurement. All of the devices tested could be expected to perform satisfactorily in most clinical settings provided that an average error of 4.0 to 8.6 mm Hg is tolerable. This level of accuracy typically extended throughout the range of pressures anticipated in most noncritical clinical situations. As implemented in the devices tested, noninvasive measurement by oscillometry with stepped deflation is more accurate than automated auscultation. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:1004 / 1012
页数:9
相关论文
共 34 条
[1]  
*AM HEART ASS, 1988, HYPERTENSION, V11, pA209
[2]  
[Anonymous], 1988, ARCH INTERN MED, V148, P1023
[3]  
[Anonymous], 1992, AM J HYPERTENS, V5, P207
[4]  
[Anonymous], 1987, AM NAT STAND EL AUT
[5]  
Association for the Advancement of Medical Instrumentation, 1993, AM NAT STAND EL AUT
[6]   CONCURRENT VALIDITY STUDIES OF BLOOD-PRESSURE INSTRUMENTATION - THE PHILADELPHIA BLOOD-PRESSURE PROJECT [J].
BARKER, WF ;
HEDIGER, ML ;
KATZ, SH ;
BOWERS, EJ .
HYPERTENSION, 1984, 6 (01) :85-91
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   NON-INVASIVE ESTIMATION OF CENTRAL AORTIC PRESSURE USING THE OSCILLOMETRIC METHOD FOR ANALYZING SYSTEMIC ARTERY PULSATILE BLOOD-FLOW - COMPARATIVE-STUDY OF INDIRECT SYSTOLIC, DIASTOLIC, AND MEAN BRACHIAL-ARTERY PRESSURE WITH SIMULTANEOUS DIRECT ASCENDING AORTIC PRESSURE MEASUREMENTS [J].
BOROW, KM ;
NEWBURGER, JW .
AMERICAN HEART JOURNAL, 1982, 103 (05) :879-886
[9]   GENESIS OF KOROTKOFF SOUNDS [J].
CHUNGCHAROEN, D .
AMERICAN JOURNAL OF PHYSIOLOGY, 1964, 207 (01) :190-&
[10]  
Davis R F, 1985, J Clin Monit, V1, P114, DOI 10.1007/BF02832198