Measurement of patient compliance

被引:58
作者
Paes, AHP
Bakker, A
Soe-Agnie, CJ
机构
[1] Univ Utrecht, Dept Pharmacoepidemiol & Pharmacotherapy, NL-3508 TB Utrecht, Netherlands
[2] Ctr Apotheek, Veldhoven, Netherlands
来源
PHARMACY WORLD & SCIENCE | 1998年 / 20卷 / 02期
关键词
data collection; oral antidiabetics; patient compliance;
D O I
10.1023/A:1008663215166
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The compliance of 91 diabetic patients using oral antidiabetic was studied. Patient compliance was measured using four different methods. Patients received their medication in a Medication Event Monitoring System (MEMS)-container. Each time the patient went back to the pharmacy for refill prescriptions, the number of tablets left in the container were counted. Pharmacy records were used to study the number of days of delay in getting the next refill. At the end of the study, a questionnaire was sent to every patient. Using MEMS asa standard, the results show that pill count and refill data overestimate the compliance of this group of patients. The MEMS data also show that the compliance data using only the number of tablets may be biased, because of possible overconsumption. Pill count does not show a correlation with compliance as measured by MEMS. The relation between compliance as measured with MEMS and refill compliance is weak.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 18 条
[1]  
BACKES JM, 1991, PATIENT COMPLIANCE M, P27
[2]  
BLOM ATG, 1992, GENEESMIDDELENBULLET, V26, P40
[3]   HOW OFTEN IS MEDICATION TAKEN AS PRESCRIBED - A NOVEL ASSESSMENT TECHNIQUE [J].
CRAMER, JA ;
MATTSON, RH ;
PREVEY, ML ;
SCHEYER, RD ;
OUELLETTE, VL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1989, 261 (22) :3273-3277
[4]  
DETULLIO PL, 1987, J CLIN PHARM THER, V12, P19
[5]  
DOWSE R, 1991, S AFR MED J, V80, P550
[6]  
ENLUND H, 1981, ACTA MED SCAND, V209, P271
[7]   A BEHAVIORAL MEDICINE PERSPECTIVE ON ADHERENCE TO LONG-TERM MEDICAL REGIMENS [J].
EPSTEIN, LH ;
CLUSS, PA .
JOURNAL OF CONSULTING AND CLINICAL PSYCHOLOGY, 1982, 50 (06) :950-971
[8]  
HERINGS RMC, 1989, EFFECTEN CHRONISCH G
[9]   SCREENING FOR NON-COMPLIANCE AMONG PATIENTS WITH HYPERTENSION - IS SELF-REPORT THE BEST AVAILABLE MEASURE [J].
INUI, TS ;
CARTER, WB ;
PECORARO, RE .
MEDICAL CARE, 1981, 19 (10) :1061-1064
[10]   ACTUAL VERSUS PRESCRIBED TIMING OF LOVASTATIN DOSES ASSESSED BY ELECTRONIC COMPLIANCE MONITORING [J].
KRUSE, W ;
NIKOLAUS, T ;
RAMPMAIER, J ;
WEBER, E ;
SCHLIERF, G .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1993, 45 (03) :211-215