Enhanced attachment of Acanthamoeba to extended-wear silicone hydrogel contact lenses -: A new risk factor for infection.?

被引:54
作者
Beattie, TK
Tomlinson, A
McFadyen, AK
Seal, DV
Grimason, AM
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4, Lanark, Scotland
[2] Glasgow Caledonian Univ, Dept Math, Glasgow G4, Lanark, Scotland
[3] City Univ London, Appl Vis Res Ctr, London EC1V 0HB, England
[4] Univ Strathclyde, Dept Civil Engn, Environm Hlth Div, Glasgow, Lanark, Scotland
关键词
D O I
10.1016/S0161-6420(02)01971-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To establish if silicone hydrogel (S-H) contact lenses could be a risk factor for Acanthamoeba infection by facilitating the attachment of trophozoites to their surface and transfer to the cornea and to determine the effect Acanthamoeba culture technique, patient wear, and Pseudomonas biofilm coating have on attachment to the S-H lens, Design: Experimental material study. Participants and Controls: Attachment to a S-H lens was compared with that of a conventional hydrogel control lens. Sixteen replicates were carried out for both lens types under each test condition., Methods: Unworn S-H (PureVision; Bausch & Lomb, Kingston-Upon-Thames UK) and conventional hydrogel (Acuvue; Vistakon, Johnson & Johnson, Jacksonville, FL USA) lens quarters were incubated for 90 minutes in suspensions of liquid or plate-cultured Acanthamoeba castellanii trophozoites. Unworn, worn, and Pseudomonas biofilm coated S-H and hydrogel quarters were incubated for 90 minutes with plate-cultured trophozoites. Main Outcome Measures. Trophozoites attached to one surface of each lens quarter were counted by direct light microscopy. Logarithmic transformation of data allowed the use of a parametric analysis of variance. Results: Lens polymer had a significant effect on attachment (P < 0.001), with higher numbers of trophozoites attaching to the S-H lens. Culture technique also had a significant effect on attachment (P = 0.013), with higher numbers of liquid-cultured organisms attaching to both lens types. A significant increase in attachment was demonstrated with worn and Pseudomonas biofilm-coated hydrogel lenses (P < 0.001); however, this difference was not seen with the S-H lens. Conclusions: Acanthamoebal attachment to the S-H lenses was significantly greater than to the conventional hydrogel. Liquid-cultured trophozoites demonstrated a higher affinity for the lenses tested. Wear and bacterial biofilm coating had no effect on attachment to S-H lenses. The increased attachment found with the S-H lens may be an inherent characteristic of the polymer or a side effect of the surface treatment procedure to which the lenses are exposed. It is possible that S-H lenses are at greater risk of promoting Acanthamoeba infection if exposed to the organism because of the enhanced attachment characteristic of this new material. (C) 2003 by the American Academy of Ophthalmology.
引用
收藏
页码:765 / 771
页数:7
相关论文
共 36 条
[1]   Incidence of contact-lens-associated microbial keratitis and its related morbidity [J].
Cheng, KH ;
Leung, SL ;
Hoekman, HW ;
Beekhuis, WH ;
Mulder, PGH ;
Geerards, AJM ;
Kijlstra, A .
LANCET, 1999, 354 (9174) :181-185
[2]   MICROBIAL-CONTAMINATION OF CONTACT-LENS CASES IN THE WEST OF SCOTLAND [J].
DEVONSHIRE, P ;
MUNRO, FA ;
ABERNETHY, C ;
CLARK, BJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (01) :41-45
[3]   Binding of Acanthamoeba to hydrogel contact lenses [J].
Gorlin, AI ;
Gabriel, MM ;
Wilson, LA ;
Ahearn, DG .
CURRENT EYE RESEARCH, 1996, 15 (02) :151-155
[4]   Effect of adhered bacteria on the binding of Acanthamoeba to hydrogel lenses [J].
Gorlin, AI ;
Gabriel, MM ;
Wilson, LA ;
Ahearn, DG .
ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (05) :576-580
[5]  
Holden Brien A, 2002, Clin Exp Optom, V85, P123
[6]   Microbial keratitis in Hong Kong: relationship to climate, environment and contact-lens disinfection [J].
Houang, E ;
Lam, D ;
Fan, D ;
Seal, D .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2001, 95 (04) :361-367
[7]   ADHERENCE OF ACANTHAMOEBA-CASTELLANII CYSTS AND TROPHOZOITES TO UNWORN SOFT CONTACT-LENSES [J].
JOHN, T ;
DESAI, D ;
SAHM, D .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (06) :658-664
[8]  
JOHN T, 1991, CLAO Journal, V17, P109
[9]  
JONES DB, 1975, T OPHTHAL SOC UK, V95, P221
[10]  
Keay Lisa, 2001, CLAO Journal, V27, P30