An investigation into the analgesic effects of interferential currents and transcutaneous electrical nerve stimulation on experimentally induced ischemic pain in otherwise pain-free volunteers

被引:66
作者
Johnson, MI [1 ]
Tabasam, G [1 ]
机构
[1] Leeds Metropolitan Univ, Sch Hlth Sci, Fac Hlth & Environm, Leeds LS1 3HE, W Yorkshire, England
来源
PHYSICAL THERAPY | 2003年 / 83卷 / 03期
关键词
analgesia; experimentally induced pain; interferential currents; submaximal effort tourniquet test; transcutaneous electrical nerve stimulation;
D O I
10.1093/ptj/83.3.208
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. Interferential currents (IFC) and transcutaneous electrical nerve stimulation (TENS) are used for pain. management. This study compared the analgesic effects of IFC and TENS on experimentally induced ischemic pain in otherwise pain-free subjects using a modified version of the submaximal-effort tourniquet technique. Subjects. The subjects were 30 volunteers (18 male, 12 female) without known pathology that could cause pain. Their mean age was 33.5 years (SD=9.9, range=21-54). Method. A single-blind, sham-controlled, parallel-group method was used. The primary outcome measure was the change in the self-report of pain intensity during 1 of 3 possible interventions: (1) IFC, (2) TENS, or (3) sham electrotherapy. The IFC and TENS were administered on the forearm, and the sham electrotherapy group received no current output via a dummy stimulator. Results. A 2-way repeated-measures analysis of variance revealed that there was no change in pain intensity during treatment when all 3 groups were considered together. Further analysis revealed that IFC reduced pain intensity when compared with sham electrotherapy but not when compared only with TENS. Discussion and Conclusion. There were no differences in the magnitude of analgesia between IFC and TENS. Interferential currents reduced pain intensity to a greater extent than sham electrotherapy.
引用
收藏
页码:208 / 223
页数:16
相关论文
共 91 条
[1]  
*AM PHYS THER ASS, 1990, EL TERM PHYS THER RE
[2]   EFFECTS OF ACUPUNCTURE AND TRANS-CUTANEOUS ELECTRICAL NERVE-STIMULATION ON COLD-INDUCED PAIN IN NORMAL SUBJECTS [J].
ASHTON, H ;
EBENEZER, I ;
GOLDING, JF ;
THOMPSON, JW .
JOURNAL OF PSYCHOSOMATIC RESEARCH, 1984, 28 (04) :301-308
[3]  
BJORDAL JM, 1998, PHYS THER REV, V3, P121
[4]   Transcutaneous electrical nerve stimulation in labour pain: A systematic review [J].
Carroll, D ;
Tramer, M ;
McQuay, H ;
Nye, B ;
Moore, A .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (02) :169-175
[5]   Randomization is important in studies with pain outcomes: Systematic review of transcutaneous electrical nerve stimulation in acute postoperative pain [J].
Carroll, D ;
Tramer, M ;
McQuay, H ;
Nye, B ;
Moore, A .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (06) :798-803
[6]  
CARROLL D, 1997, CONT REV OBSTET SEP, P195
[7]   Long-term transcutaneous electrical nerve stimulation (TENS) use: Impact on medication utilization and physical therapy costs [J].
Chabal, C ;
Fishbain, DA ;
Weaver, M ;
Heine, LW .
CLINICAL JOURNAL OF PAIN, 1998, 14 (01) :66-73
[8]  
*CHART SOC PHYS, CHART SOC PHYS STAND
[9]   PHARMACOKINETICS AND ANALGESIC EFFECT OF KETAMINE IN MAN [J].
CLEMENTS, JA ;
NIMMO, WS .
BRITISH JOURNAL OF ANAESTHESIA, 1981, 53 (01) :27-30
[10]   Lack of effect of transcutaneous electrical nerve stimulation upon experimentally induced delayed onset muscle soreness in humans [J].
Craig, JA ;
Cunningham, MB ;
Walsh, DM ;
Baxter, GD ;
Allen, JM .
PAIN, 1996, 67 (2-3) :285-289