Comparison of four different intra-articular injection sites in the knee: a cadaver study

被引:55
作者
Esenyel, Cem [1 ]
Demirhan, Mehmet
Esenyel, Meltem
Sonmez, Mesut
Kahraman, Sinan
Senel, Berna
Ozdes, Taskin
机构
[1] Vakif Gureba Training Hosp, Dept Orthopaed Surg & Traumatol, Istanbul, Turkey
[2] Istanbul Univ, Istanbul Fac Med, Dept Orthopaed & Traumatol, Istanbul, Turkey
[3] Vakif Gureba Training Hosp, Dept Phys Therapy, Istanbul, Turkey
[4] Istanbul Univ, Istanbul Fac Med, Repub Turkey Minist Justice, Council Forens Med, Cstanbul, Turkey
关键词
intra-articular injection; knee; osteoarthritis; hyaluronic acid; cadaver study;
D O I
10.1007/s00167-006-0231-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although intra-articular knee injection is not a complicated procedure, it could be difficult to assess whether the tip of the needle lies free in the joint or is embedded in synovium or other intra-articular soft tissues. The purpose of this study was to evaluate the accuracy rate of intra-articular injection using anteromedial (AM), anterolateral (AL), lateral midpatellar (LMP), and medial midpatellar (MMP) portals in cadavers. In this study 156 knees of 78 fresh cadavers were included. Anterolateral and AM injection to both knees of 39 cadavers (78 knees) were performed. MMP and LMP injection to both knees of other 39 cadavers were also performed. Accuracy rate was the highest (85%) in the AL injection portal and lowest in the MMP portal (56%). In conclusion, the accuracy obtained with use of the MMP portal was significantly lower than that obtained with the use of either the AM (P < 0.05), AL (P < 0.0001), or LMP (P < 0.05) portal. Although AL injection site resulted in good intra-articular delivery with 85% accuracy rate and with a lower incidence of soft tissue infiltration, the results were not statistically significant when compared to AM and LMP portals. Therefore, any of these three portals might be preferred depending on the experience of the physician. On the other hand, 100% accuracy could not be obtained through any portals in the study, which should be kept in mind when treating knee problems with intra-articular medications.
引用
收藏
页码:573 / 577
页数:5
相关论文
共 21 条
[1]
ADAMS ME, 1993, J RHEUMATOL, V20, P16
[2]
The role of viscosupplenentation with hylan G-F 20 (Synvisc(R)) in the treatment of osteoarthritis of the knee: A Canadian multicenter trial comparing hylan G-F 20 alone, hylan G-F 20 with non-steroidal anti-inflammatory drugs (NSAIDs) and NSAIDs alone [J].
Adams, ME ;
Atkinson, MH ;
Lussier, AJ ;
Schulz, JI ;
Siminovitch, KA ;
Wade, JP ;
Zummer, M .
OSTEOARTHRITIS AND CARTILAGE, 1995, 3 (04) :213-225
[3]
Altman RD, 1998, J RHEUMATOL, V25, P2203
[4]
[Anonymous], 2001, AM J MED SPORTS
[5]
Balazs E. A., 1982, DISORDERS KNEE, P61
[6]
BALAZS EA, 1993, J RHEUMATOL, V20, P3
[7]
Placement of intra-articular injections verified by mini air-arthrography [J].
Bliddal, H .
ANNALS OF THE RHEUMATIC DISEASES, 1999, 58 (10) :641-643
[8]
FORRESTER JV, 1980, IMMUNOLOGY, V40, P435
[9]
GHOSH P, 1994, CLIN EXP RHEUMATOL, V12, P75
[10]
Accuracy of needle placement into the intra-articular space of the knee [J].
Jackson, DW ;
Evans, NA ;
Thomas, BM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (09) :1522-1527