RITM:: A mini γ camera for pre and per-operative radio guided cancer surgery evaluation for bone tumor localization in theater blocks

被引:5
作者
Menard, L
Mastrippolito, R
Charon, Y
Laniece, P
Pinot, L
Ploux, L
Saoudi, A
Solal, M
Ricard, M
Valentin, L
机构
[1] Inst Phys Nucl, F-91406 Orsay, France
[2] Univ Paris 07, Grp Modelisat Phys Interfaces Biol, F-75005 Paris, France
[3] Inst Gustave Roussy, F-94805 Villejuif, France
[4] U66 INSERM, F-94805 Villejuif, France
关键词
D O I
10.1109/23.656450
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a multi-functional portable gamma radio-imager (RITM) based on a position sensitive photo-multiplier tube (PSPMT) in order to evaluate the potential of such a mini gamma camera concept in radio-pharmacology and nuclear medicine. We report here an evaluation of our RITM device for bone surgery. It concerns localization of the Osteoid Osteoma (benign bone tumor) performed in the theater block before skin incision and during the surgical lesion extraction. In the over 13 cases we studied, the diagnosis furnished by RITM was always confirmed by post-operation anatomopathological analysis. This shows how RITM can be used as an additional indicator to monitor. the operation. Following RITM experience, we are developing a new small field of view gamma per-operative compact imager (POCI) with submillimeter spatial resolution performance. It consists of a high resolution collimator and a YAP:Ce crystal assembly coupled to an intensified position sensitive diode (IPSD). This hand-held imaging probe is first dedicated to intra-operative monitoring for thyroid tumor and neuroblastoma removal. Characteristics of the POCI device and preliminary results are briefly presented.
引用
收藏
页码:2445 / 2449
页数:5
相关论文
共 28 条
[1]   IMAGES OBTAINED WITH A COMPACT GAMMA-CAMERA [J].
BIRD, AJ ;
RAMSDEN, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3) :480-483
[2]  
BLAZEK K, 1995, IEEE T NUCL SCI, V42, P5
[3]   A SELF TRIGGERED INTENSIFIED CCD (STIC) [J].
CHARON, Y ;
LANIECE, P ;
BENDALI, M ;
GAILLARD, JM ;
LEBLANC, M ;
MASTRIPPOLITO, R ;
TRICOIRE, H ;
VALENTIN, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) :379-384
[4]   Use of a YRP:Ce matrix coupled to a position-sensitive photomultiplier for high resolution position emission tomography [J].
DelGuerra, A ;
deNotaristefani, F ;
DiDomenico, G ;
Giganti, M ;
Pani, R ;
Piffanelli, A ;
Zavattini, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1958-1962
[5]   1ST RESULTS ON THE HYBRID PHOTODIODE TUBE [J].
DESALVO, R ;
HAO, W ;
YOU, K ;
WANG, Y ;
XU, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3) :375-384
[6]  
DURRANT P, 1995, IEEE NSS MIC C RES, V3, P1806
[7]  
Harris CC, 1956, NUCLEONICS, V14
[9]   POSITION-SENSITIVE PHOTOMULTIPLIER TUBES FOR SCINTILLATION IMAGING [J].
KUME, H ;
MURAMATSU, S ;
IIDA, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :359-363
[10]   PORTABLE GAMMA-SPECTROMETRY SYSTEM FOR SIMULTANEOUS MONITORING OF RADIOTRACERS IN-VIVO USING CDTE AND CDZNTE RADIATION DETECTOR PROBES [J].
LORENZ, M ;
VANRYN, J ;
MERK, H ;
MARKERT, M ;
EISERT, WG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :448-452