Ceasing routine use of nitrous oxide -: a follow up

被引:8
作者
Enlund, M [1 ]
Edmark, L [1 ]
Revenäs, B [1 ]
机构
[1] Cent Hosp Vasteras, Dept Anaesthesia & Intens Care, SE-72189 Vasteras, Sweden
关键词
anaesthetics gases; nitrous oxide; anaesthetics volatile; sevoflurane; anaesthetics i.v; propofol; anaesthesia; audit;
D O I
10.1093/bja/aeg108
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The role of nitrous oxide in modern anaesthesia is questioned. The routine use of nitrous oxide was almost completely stopped in our department after November 1, 2000, and we now report some consequences. Methods. Staff completed a questionnaire after 6 months, and we analysed the use of hypnotics and opioids after 12 months. The cost of drugs for the year after stopping nitrous oxide was compared with the cost 2 yr before. Results. Less than half of the 55 staff members who answered the questionnaire used nitrous oxide in the 6 months after the stop, and they did so on only a few occasions. Half of the staff members thought the benefit of nitrous oxide was small. Most supported the change. The use of opioids was stable during the study period, and there was an annual increase of 12-14% in the use of hypnotics during the 3 yr. Conclusions. The staff questionnaire showed a strong acceptance of the new policy, and the use of other anaesthetic agents did not increase as expected. Has the value of nitrous oxide been overestimated?
引用
收藏
页码:686 / 688
页数:3
相关论文
共 7 条
[1]   PLASMA-CONCENTRATIONS OF ALFENTANIL REQUIRED TO SUPPLEMENT NITROUS-OXIDE ANESTHESIA FOR GENERAL-SURGERY [J].
AUSEMS, ME ;
HUG, CC ;
STANSKI, DR ;
BURM, AGL .
ANESTHESIOLOGY, 1986, 65 (04) :362-373
[2]   EFFECTIVE CONCENTRATION 50 FOR PROPOFOL WITH AND WITHOUT 67-PERCENT NITROUS-OXIDE [J].
DAVIDSON, JAH ;
MACLEOD, AD ;
HOWIE, JC ;
WHITE, M ;
KENNY, GNC .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1993, 37 (05) :458-464
[3]   PLASMA-CONCENTRATION OF FENTANYL, WITH 70-PERCENT NITROUS-OXIDE, TO PREVENT MOVEMENT AT SKIN INCISION [J].
GLASS, PSA ;
DOHERTY, M ;
JACOBS, JR ;
GOODMAN, D ;
SMITH, LR .
ANESTHESIOLOGY, 1993, 78 (05) :842-847
[4]  
Nakahara T, 1997, Masui, V46, P607
[5]   Pharmacodynamic interaction of nitrous oxide with sevoflurane, desflurane, isoflurane and enflurane in surgical patients:: measurements by effects on EEG median power frequency [J].
Röpcke, H ;
Wirz, S ;
Bouillon, T ;
Bruhn, J ;
Hoeft, A .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2001, 18 (07) :440-449
[6]  
Schüttler J, 2001, ANASTH INTENSIV NOTF, V36, P640, DOI 10.1055/s-2001-17695
[7]   Propofol anesthesia and rational opioid selection - Determination of optimal EC50-EC95 propofol-opioid concentrations that assure adequate anesthesia and a rapid return of consciousness [J].
Vuyk, J ;
Mertens, MJ ;
Olofsen, E ;
Burm, AGL ;
Bovill, JG .
ANESTHESIOLOGY, 1997, 87 (06) :1549-1562