摘要
Background: Traditional use of gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, is inaccurate and cannot differentiate components of the gastric contents (gastric secretion us delivered formula). The use of refractometry and 3 mathematical equations has been proposed as a method to calculate the formula concentration, GRV, and formula volume. In this paper, we have validated these mathematical equations so that they can be implemented in clinical practice. Methods: Each of 16 patients receiving a nasogastric tube had 50 mL of water followed by 100 mL of dietary formula (Osmolite HN, Abbott Laboratories, Columbus, OH) infused into the stomach. After mixing, gastric content was aspirated for the first Brix value (BV) measurement by refractometry. Then, 50 mL of water was infused into the stomach and a second BV was measured. The procedure of infusion of dietary formula (100 mL) and then water (50 mL) was repeated and followed by subsequent BV measurement. The same procedure was performed in an in vitro experiment. Formula concentration, GRV, and formula volume were calculated from the derived mathematical equations. Results: The formula concentrations, GRVs, and formula volumes calculated by using refractometry and the mathematical equations were close to the true values obtained from both in vivo and in vitro validation experiments. Conclusions: Using this method, measurement of the BV of gastric contents is simple, reproducible, and inexpensive. Refractometry and the derived mathematical equations may be used to measure formula concentration, GRV, and formula volume, and also to serve as a tool for monitoring the gastric contents of patients receiving nasogastric feeding.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 26 条
[1]  
Bradley RL, 1994, INTRO CHEM ANAL FOOD, P95
[2]   Monitoring bolus nasogastric tube feeding by the Brix value determination and residual volume measurement of gastric contents [J].
Chang, WK ;
McClave, SA ;
Lee, MS ;
Chao, YC .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2004, 28 (02) :105-112
[3]   Continuous nasogastric tube feeding: monitoring by combined use of refractometry and traditional gastric residual volumes [J].
Chang, WK ;
McClave, SA ;
Chao, YC .
CLINICAL NUTRITION, 2004, 23 (01) :105-112
[4]  
Chang WK, 2003, GASTROENTEROLOGY, V124, pA429
[5]   Use of the refractometer as a tool to monitor dietary formula concentration in gastric juice [J].
Chang, WK ;
Chen, MZ ;
Chao, YC .
CLINICAL NUTRITION, 2002, 21 (06) :521-525
[6]   USE OF REFRACTOMETERS TO DETECT CONTROLLED-SUBSTANCE TAMPERING [J].
CHEUNG, JF ;
CHONG, S ;
KITRENOS, JG ;
FUNG, HL .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1991, 48 (07) :1488-1492
[7]  
DiSario James A., 2002, Journal of Parenteral and Enteral Nutrition, V26, pS75, DOI 10.1177/014860710202600612
[8]  
Edwards SJ, 2000, MEDSURG NURS, V9, P126
[9]  
FRANKENFIELD DL, 1991, AM J HOSP PHARM, V48, P2199
[10]   NEW CLINICAL METHOD FOR MEASURING RATE OF GASTRIC EMPTYING - DOUBLE SAMPLING TEST MEAL [J].
GEORGE, JD .
GUT, 1968, 9 (02) :237-&