Effect of concomitant elements on the distribution of ions in inductively coupled plasma-mass spectroscopy. Part 1. Elemental ions

被引:44
作者
Fraser, MM [1 ]
Beauchemin, D [1 ]
机构
[1] Queens Univ, Dept Chem, Kingston, ON K7L 3N6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
inductively coupled plasma-mass spectrometry; matrix effects; easily ionized elements; spatial profiling; space-charge effects; ion-atom equilibrium; ambipolar diffusion;
D O I
10.1016/S0584-8547(00)00273-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The effect of various concomitant elements in ICP-MS was assessed by measuring the distribution of selected singly charged analyte ions (of Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Mo, Sb, La, Ce, and Ph) as well as doubly charged ions of La and Ce in the plasma. This was accomplished while moving the ICP across and away from the sampling interface. The effect of each different concomitant element was studied individually. This study included concomitant elements that were similar in ionization potential but different in mass (Na, K, Cs and Cl, I) as well as similar in mass but different in ionization potential (K and Cl, Cs and I). A dependence upon both the mass of the matrix element and the mass of the analyte was observed. The suppression seen increased with increasing matrix element mass and decreased with increasing analyte mass. The effect of the mass of the matrix element was the more significant of the two factors. Space-charge effects were found to be significant for matrix elements of much lower mass than has been suggested previously. The age of the sampling interface was also found to have an effect upon the relative observed locations within the plasma of the suppressions and enhancements. Older sampling interfaces resulted in the 'crossing point', where an analyte signal in the presence of a matrix element intersects the reference analyte signal, shifting closer to the load coil. This is likely further evidence of space-charge effects. Finally, some evidence was also found fur a shift in ion-atom equilibrium through the suppression observed in the presence of 0.02 M Na, an element for which space-charge effects should be negligible. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1705 / 1731
页数:27
相关论文
共 59 条
[23]  
HALL GEM, 1989, HDB INDUCTIVELY COUP, P240
[24]   THE EFFECT OF SAMPLE MATRIX ON ELECTRON-DENSITY, ELECTRON-TEMPERATURE AND GAS TEMPERATURE IN THE ARGON INDUCTIVELY-COUPLED PLASMA EXAMINED BY THOMSON AND RAYLEIGH-SCATTERING [J].
HANSELMAN, DS ;
SESI, NN ;
HUANG, M ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (05) :495-526
[25]   LASER-EXCITED FLUORESCENCE STUDIES OF MATRIX-INDUCED ERRORS IN INDUCTIVELY COUPLED PLASMA SPECTROMETRY - IMPLICATIONS FOR ICP-MASS SPECTROMETRY [J].
HOBBS, SE ;
OLESIK, JW .
APPLIED SPECTROSCOPY, 1991, 45 (09) :1395-1407
[26]   The influence of incompletely desolvated droplets and vaporizing particles on chemical matrix effects in inductively coupled plasma spectrometry: Time-gated optical emission and laser-induced fluorescence measurements [J].
Hobbs, SE ;
Olesik, JW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (03) :353-367
[27]  
Houk R., 1986, ANAL CHEM, V58, P97
[28]   STUDY OF PLASMA POTENTIAL EFFECTS IN A 40-MHZ INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY SYSTEM [J].
JAKUBOWSKI, N ;
STUEWER, D ;
RAEYMAEKERS, BJ ;
BROEKAERT, JAC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (02) :219-228
[29]   NON-SPECTROSCOPIC MATRIX INTERFERENCES IN INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY [J].
KIM, YS ;
KAWAGUCHI, H ;
TANAKA, T ;
MIZUIKE, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (03) :333-339
[30]   Matrix effect studies in the inductively coupled plasma with monodisperse droplets. Part II: The influence of matrix on spatially integrated ion density [J].
Lazar, AC ;
Farnsworth, PB .
APPLIED SPECTROSCOPY, 1999, 53 (04) :465-470