Use of Cutometer to assess epidermal hydration

被引:113
作者
Dobrev, H [1 ]
机构
[1] Higher Med Inst, Dept Dermatol, Plovdiv 4002, Bulgaria
关键词
cutometer; corneometer; bioengineering;
D O I
10.1034/j.1600-0846.2000.006004239.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background/aims: The Cutometer equipped with a 2-mm diameter suction probe is a device suitable for assessment of epidermal mechanics. The objectives of this study were to determine the sensitivity of Cutometer parameters to epidermal hydration, to evaluate the correlation between skin mechanical parameters and skin capacitance, and to study the role of pretension of the skin. Methods: In the first study, skin capacitance (Corneometer) and 10 mechanical parameters were determined before and 60 min after application of five different moisturizers on the volar forearm. In the second study, measurements of epidermal mechanics were made without and with 0.1 s presuction of the skin. before and 120 min after application of petrolatum and glycerin. Results: Hydration of the skin significantly increased the values of capacitance and all rheological parameters. Delayed distension (U-v and viscoelastic-to-elastic ratio (U-v/U-a) were the most sensitive Cutometer parameters. Significant correlations between skin capacitance and mechanical parameters were not found. Pretension of the skin did not significantly influence the values of skin mechanical parameters. Conclusions: The non-invasive measurements of skin elasticity are appropriate for an objective and quantitative evaluation of the complex effect of different dermatological and cosmetic products on skin mechanics and hydration.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 24 条
[1]   AN INVIVO ASSESSMENT OF THE BIOMECHANICAL PROPERTIES OF HUMAN-SKIN MODIFICATIONS UNDER THE INFLUENCE OF COSMETIC PRODUCTS [J].
AUBERT, L ;
ANTHOINE, P ;
DERIGAL, J ;
LEVEQUE, JL .
INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 1985, 7 (02) :51-59
[2]  
AURIOL F, 1993, ACTA DERM-VENEREOL, V73, P344
[3]  
Barel AO, 1995, HDB NONINVASIVE METH, V106, P335
[4]  
Barel AO, 1995, HDB NONINVASIVE METH, P165
[5]  
BLICHMANN CW, 1988, ACTA DERM-VENEREOL, V68, P284
[6]   Non-invasive monitoring of the mechanical properties of keloids during cryosurgery [J].
Dobrev, H .
ACTA DERMATO-VENEREOLOGICA, 1999, 79 (06) :487-488
[7]  
Dobrev H, 1998, Skin Res Technol, V4, P155, DOI 10.1111/j.1600-0846.1998.tb00102.x
[8]   In vivo study of skin mechanical properties in scleredema of Buschke [J].
Dobrev, H .
ACTA DERMATO-VENEREOLOGICA, 1998, 78 (02) :103-106
[9]  
DOBREV H, 1998, DERMATOL VENEROL BUL, V36, P11
[10]   In vivo study of skin mechanical properties in patients with systemic sclerosis [J].
Dobrev, HP .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1999, 40 (03) :436-442