MR image analysis: Longitudinal cardiac motion influences left ventricular measurements

被引:2
作者
Berkovic, Patrick [1 ]
Hemmink, Maarten [1 ]
Parizel, Paul M. [2 ]
Vrints, Christiaan J. [1 ]
Paelinck, Bernard P. [1 ]
机构
[1] Univ Antwerp Hosp, Dept Cardiol, B-2650 Edegem, Belgium
[2] Univ Antwerp Hosp, Dept Radiol, B-2650 Edegem, Belgium
关键词
Magnetic resonance imaging; Left ventricular; Analysis; THROUGH-PLANE MOTION; MAGNETIC-RESONANCE; REPRODUCIBILITY; QUANTIFICATION; MASS; ACQUISITION; INFARCTION; VOLUMES; CINE;
D O I
10.1016/j.ejrad.2008.10.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Background: software for the analysis of left ventricular (LV) volumes and mass using border detection in short-axis images only, is hampered by through-plane cardiac motion. Therefore we aimed to evaluate software that involves longitudinal cardiac motion. Methods: Twenty-three consecutive patients underwent 1.5-Tesla cine magnetic resonance (MR) imaging of the entire heart in the long-axis and short-axis orientation with breath-hold steady-state free precession imaging. Offline analysis was performed using software that uses short-axis images (Medis MASS) and software that includes two-chamber and four-chamber images to involve longitudinal LV expansion and shortening (CAAS-MRV). Intraobserver and interobserver reproducibility was assessed by using Bland-Altman analysis. Results: Compared with MASS software, CAAS-MRV resulted in significantly smaller end-diastolic (156 +/- 48 ml versus 167 +/- 52 ml, p = 0.001) and end-systolic LV volumes (79 +/- 48 ml versus 94 +/- 52 ml, p < 0.001). In addition, CAAS-MRV resulted in higher LV ejection fraction (52 +/- 14% versus 46 +/- 13%, p < 0.001) and calculated LV mass (154 +/- 52 g versus 142 +/- 52 g,p = 0.004). Intraobserver and interobserver limits of agreement were similar for both methods. Conclusion: MR analysis of LV volumes and mass involving long-axis LV motion is a highly reproducible method, resulting in smaller LV volumes, higher ejection fraction and calculated LV mass. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:260 / 265
页数:6
相关论文
共 15 条
[1]
Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
Holman ER, 1997, CIRCULATION, V95, P924
[4]
Automated observer-independent acquisition of cardiac short-axis MR images: A pilot study [J].
Lelieveldt, BPF ;
van der Geest, RJ ;
Lamb, HJ ;
Kayser, HWM ;
Reiber, JHC .
RADIOLOGY, 2001, 221 (02) :537-542
[5]
PROGNOSTIC IMPLICATIONS OF ECHOCARDIOGRAPHICALLY DETERMINED LEFT-VENTRICULAR MASS IN THE FRAMINGHAM-HEART-STUDY [J].
LEVY, D ;
GARRISON, RJ ;
SAVAGE, DD ;
KANNEL, WB ;
CASTELLI, WP .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 322 (22) :1561-1566
[6]
NONINVASIVE QUANTIFICATION OF LEFT-VENTRICULAR MYOCARDIAL MASS BY GATED PROTON NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
MADDAHI, J ;
CRUES, J ;
BERMAN, DS ;
MERICLE, J ;
BECERRA, A ;
GARCIA, EV ;
HENDERSON, R ;
BRADLEY, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) :682-692
[7]
The influence of through-plane motion on left ventricular volumes measured by magnetic resonance imaging:: Implications for image acquisition and analysis [J].
Marcus, JT ;
Götte, MJW ;
DeWaal, LK ;
Stam, MR ;
Van der Geest, RJ ;
Heethaar, RM ;
Van Rossum, AC .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (01) :1-6
[8]
Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging [J].
Papavassiliu, T ;
Kühl, HP ;
Schröder, M ;
Süselbeck, T ;
Bondarenko, O ;
Böhm, CK ;
Beek, A ;
Hofman, MMB ;
van Rossum, AC .
RADIOLOGY, 2005, 236 (01) :57-64
[9]
LEFT-VENTRICULAR MEASUREMENTS WITH CINE AND SPIN-ECHO MR IMAGING - A STUDY OF REPRODUCIBILITY WITH VARIANCE COMPONENT ANALYSIS [J].
PATTYNAMA, PMT ;
LAMB, HJ ;
VANDERVELDE, EA ;
VANDERWALL, EE ;
DEROOS, A .
RADIOLOGY, 1993, 187 (01) :261-268
[10]
MAGNETIC-RESONANCE EVALUATION OF REGIONAL LEFT-VENTRICULAR FUNCTION - EFFECT OF THROUGH-PLANE MOTION [J].
PATTYNAMA, PMT ;
DOORNBOS, J ;
HERMANS, J ;
VANDERWALL, EE ;
DEROOS, A .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :681-685