Three-dimensional analysis of in vivo coronary stent - coronary artery interactions

被引:36
作者
Liao, R [1 ]
Green, NE [1 ]
Chen, SYJ [1 ]
Messenger, JC [1 ]
Hansgen, AR [1 ]
Groves, BM [1 ]
Carroll, JD [1 ]
机构
[1] Univ Colorado, Hlth Sci Ctr, Dept Med, Div Cardiol, Denver, CO 80262 USA
关键词
coronary angiography imaging; three-dimensional imaging; stents;
D O I
10.1023/B:CAIM.0000041950.84736.e6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stent implantation results in important three-dimensional (3D) changes in arterial geometry which may be associated with adverse events. Previous attempts to quantify these 3D changes have been limited by two-dimensional techniques. Using a 3D reconstruction technique, vessel curvatures at end-diastole (ED) and end-systole (ES) were measured before and after stent placement of 100 stents ( 3 stent cell designs, 6 stent types). After stenting, the mean curvature at ED and ES decreased by 22 and 21%, respectively, and represents a straightening effect on the treated vessel. This effect was proportional to the amount of baseline curvature as high vessel curvature predicted more profound vessel straightening. When analyzed by stent cell design, closed-cell stents resulted in more vessel straightening than other designs ( open cell or modified slotted tubes). Stent implantation resulted in the transmission of shape changes to stent ends and generated hinge points or buckling. Stent implantation creates 3D changes in arterial geometry which can be quantified using a 3D reconstruction technique.
引用
收藏
页码:305 / 313
页数:9
相关论文
共 28 条
[1]   Paired comparison of vascular wall reactions to Palmaz stents, Strecker tantalum stents, and Wallstents in canine iliac and femoral arteries [J].
Barth, KH ;
Virmani, R ;
Froelich, J ;
Takeda, T ;
Lossef, SV ;
Newsome, J ;
Jones, R ;
Lindisch, D .
CIRCULATION, 1996, 93 (12) :2161-2169
[2]   3-D reconstruction of coronary arterial tree to optimize angiographic visualization [J].
Chen, SJ ;
Carroll, JD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (04) :318-336
[3]   Quantitative analysis of reconstructed 3-D coronary arterial tree and intracoronary devices [J].
Chen, SYJ ;
Carroll, JD ;
Messenger, JC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (07) :724-740
[4]   Improved determination of biplane imaging geometry from two projection images and its application to three-dimensional reconstruction of coronary arterial trees [J].
Chen, SYJ ;
Metz, CE .
MEDICAL PHYSICS, 1997, 24 (05) :633-654
[5]  
CHEN SYJ, 1996, P SPIE MED IMAG IMAG, P103
[6]   Selection of coronary stents [J].
Colombo, A ;
Stankovic, G ;
Moses, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (06) :1021-1033
[7]   RESULTS OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY OF HIGH-RISK ANGULATED STENOSES [J].
ELLIS, SG ;
TOPOL, EJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (12) :932-937
[8]   ANGIOGRAPHIC AND CLINICAL PREDICTORS OF ACUTE CLOSURE AFTER NATIVE VESSEL CORONARY ANGIOPLASTY [J].
ELLIS, SG ;
ROUBIN, GS ;
KING, SB ;
DOUGLAS, JS ;
WEINTRAUB, WS ;
THOMAS, RG ;
COX, WR .
CIRCULATION, 1988, 77 (02) :372-379
[9]   STENT-INDUCED INTIMAL HYPERPLASIA - ARE THERE FUNDAMENTAL DIFFERENCES BETWEEN FLEXIBLE AND RIGID STENT DESIGNS [J].
FONTAINE, AB ;
SPIGOS, DG ;
EATON, G ;
DOSPASSOS, S ;
CHRISTOFORIDIS, G ;
KHABIRI, H ;
JUNG, S .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) :739-744
[10]   Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events [J].
Gyöngyösi, M ;
Yang, P ;
Khorsand, A ;
Glogar, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) :1580-1589