Multislice helical CT: Image temporal resolution

被引:32
作者
Hu, H [1 ]
Pan, TS
Shen, Y
机构
[1] ImagingTech Inc, Waukesha, WI 53186 USA
[2] GE Co, Milwaukee, WI 53201 USA
基金
美国国家科学基金会;
关键词
helical CT; multidetector-row CT; multislice CT; temporal resolution;
D O I
10.1109/42.870249
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A multislice helical computed tomography (CT) halfscan (HS) reconstruction algorithm is proposed for cardiac applications. The imaging performances tin terms of the temporal resolution, a-axis resolution, image noise, and image artifacts) of the HS algorithm are compared to the existing algorithms using theoretical models and clinical data. A theoretical model of the temporal resolution performance tin terms of the temporal sensitivity profile) is established for helical CT, in general, i.e,, for any number of detector rows and any reconstruction algorithm used. It is concluded that the HS reconstruction results in improved image temporal resolution than the corresponding 180 degrees LI (linear interpolation) reconstruction and is more immune to the inconsistent data problem induced by cardiac motions. The temporal resolution of multislice helical CT with the HS algorithm is comparable to that of single-slice helical CT with the HS algorithm. In practice, the 180 degrees LI and HS-LI algorithms can be used in parallel to generate two image sets from the same scan acquisition, one (180 degrees LI) for improved z-resolution and noises, and the other (HS-LI) for improved image temporal resolution.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 20 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]  
ARENSON JS, 1993, DUAL SLICE SCANNER
[3]  
BOYD DP, 1983, P IEEE, V71, P281
[4]   COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[5]   The effect of helical pitch and beam collimation on the lesion contrast and slice profile in helical CT imaging [J].
Hu, H ;
Fox, SH .
MEDICAL PHYSICS, 1996, 23 (12) :1943-1954
[6]   Helical CT reconstruction with longitudinal filtration [J].
Hu, H ;
Shen, Y .
MEDICAL PHYSICS, 1998, 25 (11) :2130-2138
[7]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[8]  
HU H, 1998, SCI ASS ANN M RAD SO, P323
[9]  
HU H, 1998, SCI ASS ANN M RAD SO, P283
[10]  
HU H, 1999, P SPIE MED IMAGING, V3361, P450