Kinetic study of membrane extraction with a sorbent interface for air analysis

被引:27
作者
Luo, YZ
Adams, M
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Guelph Waterloo Ctr Grad Work Chem, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Waterloo Ctr Groundwater Res, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac970549p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the theory and experimental implementation of the technique of membrane extraction with a sorbent interface for air analysis. A mathematical model was derived to predict the extraction process and the significant factors, such as membrane length and carrier gas flow rate. A benzene/nitrogen standard gas mixture was generated by the permeation tube method. Several parameters that affect the extraction efficiency are discussed. Among them, the membrane length, the flow rate of the carrier gas, and temperature strongly affected the extraction rate of analyte. The results demonstrated that the extraction rate of benzene was decreased with increase of the extraction temperature. Toluene, hexane, ethylbenzene, and trichloroethylene were selected to test the theory, and good agreement between theoretical predictions and experimental results was observed. The estimation of air concentration without experimental calibration is discussed. In the proposed estimation method, the diffusion coefficient of benzene in the membrane and the distribution constant between air and the membrane were measured experimentally.
引用
收藏
页码:248 / 254
页数:7
相关论文
共 23 条
[11]  
Pawliszyn J., 1997, SOLID PHASE MICROEXT
[12]   GAS EXTRACTION KINETICS OF VOLATILE ORGANIC-SPECIES FROM WATER WITH A HOLLOW FIBER MEMBRANE [J].
PRATT, KF ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2101-2106
[13]   WATER MONITORING-SYSTEM BASED ON GAS EXTRACTION WITH A SINGLE HOLLOW FIBER MEMBRANE AND GAS-CHROMATOGRAPHIC CRYOTRAPPING [J].
PRATT, KF ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2107-2110
[14]  
Skelland AHP., 1974, DIFFUSIONAL MASS TRA
[15]  
STERN S, 1995, MEMBRANE SEPARATION
[16]   FLAME IONIZATION DETECTOR RESPONSE FACTORS FOR COMPOUND CLASSES IN QUANTITATIVE-ANALYSIS OF COMPLEX ORGANIC MIXTURES [J].
TONG, HY ;
KARASEK, FW .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :2124-2128
[17]  
Vieth W. R, 1991, DIFFUSION POLYM PRIN
[18]  
Winberry W, 1988, EPA600489017
[19]  
YANG MJ, 1994, CHEMTECH, V24, P31
[20]   Kinetic model of membrane extraction with a sorbent interface [J].
Yang, MJ ;
Adams, M ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2782-2789