Inaccuracies of a plastic "pinna" SAM for SAR testing of cellular telephones against IEEE and ICNIRP safety guidelines

被引:18
作者
Gandhi, OP [1 ]
Kang, G
机构
[1] Univ Utah, Elect & Comp Engn Dept, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Elect & Comp Engn, Salt Lake City, UT 84112 USA
关键词
comparison of specific absorption rate (SAR); obtained for specific anthropomorphic mannequin (SAM) and anatomic models; considerably lower SAR for SAM; accurate SAR obtained with a proposed modified SAM;
D O I
10.1109/TMTT.2004.832689
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 2-mm-thick plastic shell with 5-10-mm-thick tapered plastic spacer in the shape of a "pinna"-specific anthropomorphic mannequin (SAM) head model is being used for determination of the specific absorption rate (SAR) of cellular telephones for compliance testing against IEEE and the International Commission on Non-Ionizing Radiation Protection (ICNIRP) Safety Guidelines used in the U.S. and Europe, respectively. We have used three-dimensional computer-aided design files of the SAM Model with 1-mm resolution to calculate peak 1- and 10-g SAR for "cheek" and "15degrees-tilted" positions of some typical telephones for comparison with those for three anatomic models of the head to show that the SAR obtained for SAM is up to two or more times smaller than for anatomic models. This is due to the shift of the high SAR locations to a low radiated fields region away from the antenna, particularly at 835 MHz, and a substantial physical separation from the absorptive phantom at 1900 MHz. Due to the use of lossless plastic for the "pinna," another handicap of the SAM model is the total lack of knowledge of 1- or 10-g SAR in the pinna tissues required by all safety guidelines (current or proposed). To remedy this situation, we propose a modified SAM with a lossy "pinna," for which 1- and 10-g SARs are relatively close to those for anatomic models, provided we use a fluid of higher conductivity than that currently used for compliance testing at 835 MHz. Lastly, we compare the implications of the current IEEE and ICNIRP guidelines and the newly proposed IEEE guidelines with a relaxed limit of 4.0 W/kg for any 10-g of tissue of the pinna for maximum allowable powers for cellular telephones at 835 and 1900 MHz to show that the newly proposed relaxed IEEE limits will allow radiated powers that may be 8-16 times those permitted by the current IEEE Standard and up to two times higher than those permitted under ICNIRP guidelines used in over 30 countries.
引用
收藏
页码:2004 / 2012
页数:9
相关论文
共 21 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
[Anonymous], C9532002 IEEE
[3]  
[Anonymous], 1999, C951 IEEE
[4]   ELECTROMAGNETIC ENERGY EXPOSURE OF SIMULATED USERS OF PORTABLE CELLULAR TELEPHONES [J].
BALZANO, Q ;
GARAY, O ;
MANNING, TJ .
IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 1995, 44 (03) :390-403
[5]  
*CENELEC, 2001, BAS STAND MEAS SPEC
[6]   SAR CALCULATIONS IN AN ANATOMICALLY REALISTIC MODEL OF THE HEAD FOR MOBILE COMMUNICATION TRANSCEIVERS AT 900-MHZ AND 1.8-GHZ [J].
DIMBYLOW, PJ ;
MANN, SM .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10) :1537-1553
[7]   Electromagnetic absorption in the human head and neck for mobile telephones at 835 and 1900 MHz [J].
Gandhi, OP ;
Lazzi, G ;
Furse, CM .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) :1884-1897
[8]   Some present problems and a proposed experimental phantom for SAR compliance testing of cellular telephones at 835 and 1900 MHz [J].
Gandhi, OP ;
Kang, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09) :1501-1518
[9]   Electromagnetic absorption in the human head from experimental 6-GHz handheld transceivers [J].
Gandhi, OP ;
Chen, JY .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1995, 37 (04) :547-558
[10]  
*IEEE, 2003, 1528 IEEE