Separation high voltage field driven on-chip amperometric detection in capillary electrophoresis

被引:50
作者
Klett, O [1 ]
Nyholm, L [1 ]
机构
[1] Uppsala Univ, Dept Analyt Chem, SE-75124 Uppsala, Sweden
关键词
D O I
10.1021/ac020660h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new potentiostatless detection scheme for amperometric detection in capillary electrophoresis is presented based on the use of microband array electrodes positioned in the capillary electrophoresis electric field. In the present study, the spatial potential difference in the CE separation high-voltage field was measured using two gold microband electrodes positioned in the proximity of the capillary outlet. The induced potential difference between the two electrodes was recorded as a function of the applied separation high voltage and the dependence of the electrochemically generated current on the high-voltage field, and the concentration of a redox couple (Fe(CN)(6)(4-)/Fe(CN)(6)(3-)) was investigated. The results show that plots of the generated current versus the CE separation voltage have the same shape as cyclic voltammograms obtained with the same electrodes in a traditional potentiostatic setup and that the current is proportional to the concentration of the redox couple. As a decoupling device is not needed, the described potentiostatless approach significantly simplifies the instrumental setup for amperometric detection. This approach consequently holds great promise for application in inexpensive portable chip-based CE devices.
引用
收藏
页码:1245 / 1250
页数:6
相关论文
共 35 条
[1]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[2]   A chip-based electrophoresis system with electrochemical detection and hydrodynamic injection [J].
Backofen, U ;
Matysik, FM ;
Lunte, CE .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4054-4059
[3]   Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device [J].
Baldwin, RP ;
Roussel, TJ ;
Crain, MM ;
Bathlagunda, V ;
Jackson, DJ ;
Gullapalli, J ;
Conklin, JA ;
Pai, R ;
Naber, JF ;
Walsh, KM ;
Keynton, RS .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3690-3697
[4]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[5]  
2-7
[6]   Microfabricated structures for integrated DNA analysis [J].
Burns, MA ;
Mastrangelo, CH ;
Sammarco, TS ;
Man, FP ;
Webster, JR ;
Johnson, BN ;
Foerster, B ;
Jones, D ;
Fields, Y ;
Kaiser, AR ;
Burke, DT .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (11) :5556-5561
[7]   Integrated chip-based capillary electrophoresis [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A .
ELECTROPHORESIS, 1997, 18 (12-13) :2203-2213
[8]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192
[9]   Portable capillary electrophoresis instrument with amperometric, potentiometric and conductometric detection [J].
Kappes, T ;
Galliker, B ;
Schwarz, MA ;
Hauser, PC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (03) :133-139
[10]   Elimination of nigh-voltage field effects in end column electrochemical detection in capillary electrophoresis by use of on-chip microband electrodes [J].
Klett, O ;
Björefors, F ;
Nyholm, L .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1909-1915